Product Details

Compaq StorageWorks About This Card
This card identifies the contents of the universal mounting kit
and provides procedures for mounting Fibre Channel 8-port
Fibre Channel (380591B21/ DSDSGGAAA or 176219B21/
DSDSGGCAA) and 16-port (380578B21/
DSDSGGAAB or 212776B21/DSDSGGCAB) switches
Switch, 8-/16-Port into the following Compaq racks:
RETMA 41U or 42U
Universal Compaq Classic
Metric SW600
Mounting Kit Kit Contents
1
4
2 3
Open Card Completely Before CXO7467B
Beginning Installation Procedures NOTE: This kit contains parts for multiple rack installations. Not all kit parts
are needed for all rack installations.
1 Mounting brackets (2)
2 Extender brackets (2)
2001 Compaq Information Technologies Group, L.P.
3 Slide brackets (2)
Compaq, the Compaq logo, and StorageWorks are trademarks of Compaq
Information Technologies Group, L.P. 4 Bag of miscellaneous hardware:
All other product names mentioned herein may be trademarks of their
Snap-on cable ties (2)
respective companies.
Compaq shall not be liable for technical or editorial errors or omissions Clip nuts (4)
contained herein. The information is provided "as is" without warranty of
any kind and is subject to change without notice. The warranties for Alignment washers (8)
Compaq products are set forth in the express limited warranty statements
Pan head SEMS screws, 10-32 x 9/32 inches (4)
accompanying such products. Nothing herein should be construed as
constituting an additional warranty.
Pan head SEMS screws, 10-32 x 5/8 inches (16)
Printed in the U.S.A.
Flat washers for #10 screws (4)
Pan head SEMS screws, 8-32 x 1/4 inches (4)
Flat washers for #8 screws (4)
Tools Required
No. 2 Phillips screwdriver
Fibre Channel Switch, 8-/16-Port Universal Mounting Kit
Third Edition (November 2001)
Par t Number: EK-GGAAB-IA. C01
Compaq Computer Corporation
Installation Process Orientation For 1.5U 16-port switches, see Figure 2.
The current or planned configuration of rack components
2
determines which installation process orientation to follow. A
key consideration is whether the cables are routed at the front
or rear of the rack.
General rack configuration guidelines include:
For RETMA 41U and metric SW600 racks, follow Uppe
r loca
procedures as oriented from the rack-front. tion
Lowe
For RETMA 42U and Compaq Classic racks, either r loca
tion
orientation--rack-front or rack-rear--configuration is
possible. Install as desired.
Beginning the Installation Process
If available, use the rack-mounting template shipped with the
8- or 16-port switch to determine the installation location CXO7518A
within the rack. Otherwise, read this section and mark rail
holes as required, using a mounting bracket.
For 2U 16-port switches, see Figure 3.
IMPORTANT: Ensure that the template-front and back are used according
to the desired installation orientation. In rack-front installations, the
template-front is used at the rack-front and template-back is used at the
3
rack-rear. In rack-rear installations, the template-front is used at the
rack-rear and template-back is used at the rack-front.
1. Position the template-front on the vertical rails to match the
template hole pattern to the rail holes.
For 8-port switches, see Figure 1.
1
CXO6804C
2. Pencil-mark the front mounting bracket holes with an M.
3. Position the template-back on the rack-rear vertical rails,
aligning the template parallel with the rack-front pencil
markings.
4. Pencil-mark the rear mounting bracket holes with an M.
CXO6800B
Page 2
Attaching the Mounting Brackets RETMA 42U and Compaq Classic Racks
1. Connect an extender bracket to each mounting bracket (see
Attach two mounting brackets, using the appropriate procedure
Figure 5) and finger-tighten two pan head SEMS screws
for the rack type.
(10-32 x 5/8 inches).
WARNING: To reduce the risk of personal injury or equipment
damage during installation, never extend multiple
5
components installed in the rack at the same time. A rack
may become unstable if more than one component is
extended for any reason.
RETMA 41U Racks
1. Position each mounting bracket (see Figure 4, 1) with the
rail holes pencil-marked M.
IMPORTANT: Finger-tighten all three mounting bracket screws to
facilitate alignment. Then secure screws in the top and bottom
mounting bracket holes prior to securing the single screw at the rear of
the bracket. Ensure that the mounting bracket is parallel in the rack
from front to back. CXO6784B
2. Install a clip nut 2 and secure, using pan head SEMS
screws (10-32 x 5/8 inches). 2. Position each mounting bracket behind the vertical rail,
aligning it with the rail holes pencil-marked M.
3. Secure each mounting bracket using alignment washers and
4 pan head SEMS screws (10-32 x 5/8 inches) as shown in
Figure 6.
IMPORTANT: Position each alignment washer to mate smoothly against
the vertical rail prior to fully tighting the screw.
2
2
6
1
1
CXO6783B
CXO6785B
4. Fully tighten the four screws installed in step 1 (see
Figure 5).
IMPORTANT: To establish full strength of the extended bracket, ensure
that screws bonding the mounting bracket and extender bracket are
fully tightened prior to proceeding.
Page 3
Metric Racks For newer 8-port switches
(176219B21/DSDSGGCAA), see Figures 9 and 10.
1. Position each mounting bracket (see Figure 7, 1) with the
Use four pan head SEMS screws (8-32 x 1/4 inches) and
rail holes pencil-marked M. four flat washers to attach the mounting brackets to the
switch.
2. Identify clip nut 2 mounting holes and install two clip nuts
IMPORTANT: Attach the slide brackets using a flat washer with each
for each mounting bracket.
screw. Without the flat washers, the screws may contact components
3. Secure each mounting bracket, using pan head SEMS inside the switch chassis.
screws (10-32 x 5/8 inches). NOTE: Install this 8-port switch with the cables at either the front or the
rear of the rack.
-- For cable-front installations, attach the brackets as
7 shown in Figure 9.
9
2
2
1
1
CXO7503B
CXO6840B
Attaching the Slide Brackets
Secure two slide brackets to each switch.
-- For cable-rear installations, attach the brackets as
shown in Figure 10.
CAUTION: Ensure that the mounting screws are the proper length
and that flat washers are used. Installing screws longer than 9/32
inch or without a flat washer may damage the switch.
10
For older 8-port switches (380591B21/ DSDSGGAAA)
in rack-front and rear installations, see Figure 8.
Use four pan head SEMS screws (10-32 x 9/32 inches) and
four flat washers to attach the mounting brackets to the
switch.
IMPORTANT: Attach the slide brackets using a flat washer with each
screw. Without the flat washers, the screws contact with the power
supply assembly inside the switch chassis.
CXO7504B
8
CXO7468B
Page 4
For 1.5U 16-port switches (such as 212776B21/ -- For cable-rear installations in an upper location, attach
DSDSGGCAB)--Positioned approximately three inches the brackets as shown in Figure 13.
from the rack front for cable-front installations (see
Figures 11 and 12), or one inch from the rack-front for
cable-rear installations (see Figures 13 and 14).
13
Use four pan head SEMS screws (10-32 x 9/32 in) and four
flat washers to attach the mounting brackets to the switch.
NOTE: Install this 16-port switch with the cables at either the front or
the rear of the rack.
This switch is 1.5U (1.75 in) in height and may be installed in pairs,
using a second universal mounting kit to occupy a 3U space in the rack.
References to upper and lower location--the top 1.5U or bottom
1.5U--are used to indicate the placement of the switch within a 3U
space. Mount the switch so that no gap exists between the switch and
the nearest enclosure.
-- For cable-front installations in an upper location, attach CXO7521B
the brackets as shown in Figure 11.
11 -- For cable-rear installations in a lower location, attach
the brackets as shown in Figure 14.
14
CXO7519B
-- For cable-front installations in a lower location, attach CXO7522B
the brackets as shown in Figure 12.
12
CXO7520B
Page 5
Installing the Switch into the Rack
For 2U 16-port switches (such as 380578B21/
DSDSGGAAB) in rack-front and rack-rear installations,
see Figures 15 and 16.
CAUTION: Keep the switch parallel to the floor while sliding the
Use four pan head SEMS screws (10-32 x 9/32 inches) and
slide brackets into the mounting brackets. Tilting the switch up or
four flat washers to attach the mounting brackets to the
down may result in damage to the brackets.
switch.
-- For rack-front installations, attach the brackets as
shown in Figure 15. IMPORTANT: All switches use the same cable routing method, so a
representative example is used here to illustrate this process.
Insert the switch slide brackets into the rack mounting brackets
15 until fully seated, and secure the front and rear, using pan head
SEMS screws (10-32 x 5/8 inches).
Secure the front of the switch as shown in Figure 17
(representative example).
17
CXO7469B
-- For rack-rear installations, attach the brackets as shown
in Figure 16.
16 CXO7190A
Secure the rear of the switch as shown in Figure 18
(representative example).
18
CXO7470B
CXO7191A
Page 6
Routing Power and Data Cables
IMPORTANT: All switches use the same cable routing method, so a
representative example is used here to illustrate this process.
Install a snap-on cable tie into each slide bracket, as shown in
Figure 19 (representative example), as desired, and route the
power cables downward along the rack vertical rail. Route data
cables based upon the current or planned rack configuration.
19
CXO7192A
This completes the hardware installation.
Page 7
EK-GGAAB-IA
Page 1 -

3prime solutions for all your Digital requirements

     
 


HP is a registered trademark