SDCM Server Hardware Kit Installation Instructions First Edition (September 2001) Part Number: AA-RR26A-TE Compaq Computer Corporation 2001 Compaq Computer Corporation. Compaq, the Compaq logo, and StorageWorks Registered in U. S. Patent and Trademark Office. All other product names mentioned herein may be trademarks of their respective companies. Confidential computer software. Valid license from Compaq required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. Compaq shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without notice. The warranties for Compaq products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. Compaq service tool software, including associated documentation, is the property of and contains confidential technology of Compaq Computer Corporation. Service customer is hereby licensed to use the software only for activities directly relating to the delivery of, and only during the term of, the applicable services delivered by Compaq or its authorized service provider. Customer may not modify or reverse engineer, remove, or transfer the software or make the software or any resultant diagnosis or system management data available to other parties without Compaq's or its authorized service provider's consent. Upon termination of the services, customer will, at Compaq's or its service provider's option, destroy or return the software and associated documentation in its possession. Printed in the U.S.A. SDCM Server Hardware Kit Installation Instructions First Edition (September 2001) Part Number: AA-RR26A-TE Contents About this Guide Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Symbols in Text. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Symbols on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Getting Help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Compaq Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii Compaq Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix Compaq Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix SDCM Server Hardware Kit Installation Instructions Carton Contents Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Installing the SDCM Server Hardware Kit in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 About This Document This document provides step-by-step instructions for setting up the SAN Director Connectivity Manager (SDCM) Server Hardware Kit in a Compaq 9000 Series, or comparable rack. Related Documents The Compaq StorageWorks documentation listed in Table 1 provides additional information about the SAN Director 64. Table 1 Related Documents Document Title Part Number Compaq StorageWorks SAN Director 64 Installation Guide AA-RQZQA-TE Compaq StorageWorks SAN Director 64 Release Notes AA-RQZRA-TE Compaq StorageWorks SANworks Director Connectivity AA-RPL7A-TE Manager User Guide Compaq SANworks SAN Director 64 Product Manager User Guide AA-RPL9A-TE Compaq StorageWorks SAN Director 64 Planning Guide AA-RPLAA-TE Compaq StorageWorks SAN Director 64 Service Manual AA-RPL8A-TE Compaq 9000 Series Rack Products Reference Guide 142553-002 Compaq StorageWorks 64 Fibre Port Module Kit AA-RQZNA-TE Installation Instructions Compaq StorageWorks SDCM Server Hardware Kit Installation AA-RR26A-TE Instructions (this document) Compaq M-Series Rack Installation Instructions AA-RQZPA-TE vi SDCM Server Hardware Installation Kit Symbols in Text These symbols may be found in the text of this guide. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or loss of information. IMPORTANT: Text set off in this manner presents clarifying information or specific instructions. NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of information. Symbols on Equipment These icons may be located on equipment in areas where hazardous conditions may exist. Any surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of injury from electrical shock hazards, do not open this enclosure. Any RJ-45 receptacle marked with these symbols indicates a Network Interface Connection. WARNING: To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle. About This Document vii Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching. Power supplies or systems marked with these symbols indicate the equipment is supplied by multiple sources of power. WARNING: To reduce the risk of injury from electrical shock, remove all power cords to completely disconnect power from the system. Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely. WARNING: To reduce the risk of personal INJURY or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling. Rack Stability WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that: s The leveling jacks are extended to the floor. s The full weight of the rack rests on the leveling jacks. s The stabilizing feet are attached to the rack if it is a single rack installation. s The racks are coupled together in multiple rack installations. s Only one component is extended at a time. A rack may become unstable if more than one component is extended for any reason. s Heaviest components are installed at the bottom of the rack. viii SDCM Server Hardware Installation Kit Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Compaq Technical Support In North America, call the Compaq Technical Phone Support Center at 1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week. NOTE: For continuous quality improvement, calls may be recorded or monitored. Outside North America, call the nearest Compaq Technical Support Phone Center. Telephone numbers for world wide Technical Support Centers are listed on the Compaq Website. Access the Compaq Website by logging on to the Internet at http://www.compaq.com. Be sure to have the following information available before you call Compaq: s Technical support registration number (if applicable) s Product serial numbers s Product model names and numbers s Applicable error messages s Add-on boards or hardware s Third-party hardware or software s Operating system type and revision level s Detailed, specific questions About This Document ix Compaq Website The Compaq website has the latest information on this product as well as the latest drivers, http://www.compaq.com. Compaq Authorized Reseller For the name of your nearest Compaq Authorized Reseller: s In the United States, call 1-800-345-1518. s In Canada, call 1-800-263-5868. s Elsewhere, see the Compaq Website for locations and telephone numbers. SDCM Server Hardware Kit Installation Instructions Use these instructions to install the SAN Director Connectivity Manager (SDCM) Hardware Kit into a Compaq 9000 Series, or comparable rack. Carton Contents Checklist Verify that the following items shipped in the SDCM Server Hardware Kit. See Figure 1. NOTE: The SDCM Server Hardware Kit uses velcro to secure the laptop and Zip drive in the shelf. To ensure that components do not shift, do not remove the velcro. s Laptop with preloaded SDCM software s Laptop AC adapter and adapter power cord s Zip drive with data cable, AC adapter and power cord s Management server slide out shelf (universal), with mounting hardware s Two 100 MB blank Zip disks s Zip disk software pack 2 SDCM Server Hardware Kit Installation Instructions 1 2 3 4 5 6 SHR-2310 1 4 Bottom Tray Zip Drive 2 5 Zip Drive AC Adapter SDCM Server 3 6 Laptop AC Adapter Sliding Shelf Figure 1: SDCM Server Hardware Kit components SDCM Server Hardware Kit Installation Instructions 3 Installing the SDCM Server Hardware Kit in a Rack Complete the following steps to install the SDCM Server Hardware Kit into a Compaq 9000 Series, or comparable rack. NOTE: The SDCM Hardware Kit installs in most racks, using the supplied adjustable rail extensions. For example, the kit accommodates both the Compaq 9000 Series and Compaq M- Series racks. 1. Select an appropriate location to install the kit in the rack. The SDCM Server Hardware Kit requires approximately 2.25 in. or 1.3U of space in the rack. Install the kit one hole higher than the standard 1U location. NOTE: If installing three or more switches, Compaq recommends installing the SDCM Server and shelf in the middle of the rack. 2. Insert the eight cage nuts provided as follows. Four cage nuts install at the front of the rack, four cage nuts install at the rear of the rack. a. On the front of the rack, locate the appropriate screw holes, based on the rack position determined in step 1. b. Insert a cage nut in the topmost screw hole, one hole above the start of one rack Unit. c. Repeat steps 2a and 2b for each of three cage nuts. d. On the rear of the rack, insert the four cage nuts that correspond with the cage nuts you installed in the front of the rack. 4 SDCM Server Hardware Kit Installation Instructions 3. Prior to positioning the SDCM Server and shelf in the rack, remove the rail extensions as follows. See Figure 2. a. Slide the shelf forward, exposing the four screws that secure the rail extensions. b. Remove the two screws from each rail extension. Put aside in a safe place as you will need these screws to reinstall the rail extensions (see step 5). c. Slide out the rail extensions. SHR-2317 Figure 2: Removing the rail extensions SDCM Server Hardware Kit Installation Instructions 5 4. Install the kit as follows. See Figure 3. NOTE: To properly orient the SDCM Hardware Kit in the rack, installation requires two technicians. Position one technician at the front of the rack, and one technician at the rear of the rack. a. To avoid tipping the shelf kit, hold the the kit firmly, placing one hand at the front of the tray and one hand at the rear of the tray. b. Lift the shelf kit, and position at the front of the rack. c. Align the shelf kit with the cage nuts installed earlier (see step 2). d. From the front of the rack, slide the shelf kit forward into the rack. SHR-2318 Figure 3: Positioning the server shelf kit in the rack e. Loosely attach the server shelf kit to the rack using the four screws provided. 6 SDCM Server Hardware Kit Installation Instructions 5. Reinstall the two rail extensions as follows. See Figure 2. a. Slide the top tray forward. b. Insert one rail extension (to where it was previously installed) between the bottom tray bracket and the slide rail. The slide rail attaches to the bottom shelf. c. Adjust the the rail extension to the appropriate length, depending on the depth of the rack. NOTE: For example, the Compaq 9000 Series rack requires a longer rail extension. The Compaq M-Series rack requires a shorter rail extension. d. Loosely secure the rail extension to the inner segment of the shelf rails. e. Repeat steps 5a through 5d for the corresponding rail extension. NOTE: Before tightening the screws for each rail extension, it is important to secure the shelf rails to the front and rear of the rack with the four screws provided. When the shelf is secure, continue with step f. f. Secure the rail extensions with the four screws provided. g. Slide the shelf to the back of the rack. 6. Connect cables as follows. a. Connect the two power cords to an equipment rack power strip. b. Attach the Ethernet cable to a device with an Ethernet port. IMPORTANT: Make sure to use the Ethernet connection located on the side of the laptop. Presently, the Ethernet connection on the laptop's motherboard is non-functional. 7. Remove the laptop from its packaging. 8. Locate the velcro pads on the server shelf and then remove the paper backing to expose the adhesive. 9. Position the laptop as shown in Figure 1. Press the bottom of the laptop onto the adhesive on the velcro pads. 10. Connect the data cable between the laptop server's parallel port and the Zip drive. 11. Connect the Ethernet cable to the PCMCIA Ethernet card located on the right side of the laptop computer. 12. Plug in the power supply adapter cable.
| 142553-002 AA-RPL7A-TE AA-RPL8A-TE AA-RPL9A-TE AA-RPLAA-TE AA-RQZNA-TE AA-RQZPA-TE AA-RQZQA-TE AA-RQZRA-TE AA-RR26A-TE |