Product Details

Compaq StorageWorks
SAN Director 64
Installation Guide
First Edition (September 2001)
Part Number: AA-RQZQA-TE
Compaq Computer Corporation
2001 Compaq Computer Corporation.
Compaq, the Compaq logo, SANworks, and StorageWorks are trademarks of Compaq Information
Technologies Group, L.P.
Microsoft, Windows, Windows NT are trademarks of Microsoft Corporation in the United States and
other countries.
Intel, Pentium, and Celeron are trademarks of Intel Corporation in the United States and other countries.
UNIX is a trademark of The Open Group in the United States and other countries.
All other product names mentioned herein may be trademarks of their respective companies.
Confidential computer software. Valid license from Compaq required for possession, use or copying.
Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The
information in this document is provided "as is" without warranty of any kind and is subject to change
without notice. The warranties for Compaq products are set forth in the express limited warranty
statements accompanying such products. Nothing herein should be construed as constituting an additional
warranty.
Compaq service tool software, including associated documentation, is the property of and contains
confidential technology of Compaq Computer Corporation. Service customer is hereby licensed to use
the software only for activities directly relating to the delivery of, and only during the term of, the
applicable services delivered by Compaq or its authorized service provider. Customer may not modify or
reverse engineer, remove, or transfer the software or make the software or any resultant diagnosis or
system management data available to other parties without Compaq's or its authorized service provider's
consent. Upon termination of the services, customer will, at Compaq's or its service provider's option,
destroy or return the software and associated documentation in its possession.
Printed in the U.S.A.
SAN Director 64 Installation Guide
First Edition (September 2001)
Part Number: AA-RQZQA-TE
Contents
About This Guide
Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Symbols in Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Symbols on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Compaq Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Compaq Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Compaq Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Chapter 1
Overview
SAN Director 64 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SAN Director 64 Hardware Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Front View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
CTP Card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Front Bezel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Cable Management Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
FPM Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Rear View. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
SBAR Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Power Module Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
SAN Director 64 Optional Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Chapter 2
Installing and Configuring the SAN Director 64
Review Installation Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Items Required for Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Select an Operating Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Cooling and Power Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
iv SAN Director 64 Installation Guide
Unpack and Inspect the Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Install the Director in a 9000 Series Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Tips for Installing More than One Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Transfer the Director to the Lift Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Install the Shelf Brackets in the 9000 Series Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Prepare the Switch for Install. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Secure the Mounting Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Insert the Cage Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Insert the Front Cage Nuts in the Rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Insert the Rear Cage Nuts in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Finalize the Rack Mounting Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
Power-On Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Configure Director Network Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Changing the Director's IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
LAN-Connect the Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
SDCM Server Hardware Kit Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
SDCM Software Kit Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
SDCM Server Hardware Kit Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Install the SDCM Server Hardware Kit in a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
Connect the SDCM Server to the LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
Configure the SDCM Server Addressing Information . . . . . . . . . . . . . . . . . . . . . . . . . 227
Set SDCM Server Date and Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
Assign SDCM User Names and Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Enabling SDCM to Manage the Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Verify Communication Between the Director and SDCM Server . . . . . . . . . . . . . . . . 239
Set Director Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Set Date and Time Manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Synchronize Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Frequently Used SDCM Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243
Set the Director Online . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Set the Director Offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
Configure Director Identification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
Configure Operating Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Configure Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Configure Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
Configure SNMP Trap Message Recipients . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Configure and Enable Email Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Configure and Enable the Call-Home Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Set Up Call-Home. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
Test Remote Notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Connect the Cables to the Fibre Channel Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Contents v
Connect the Director to a Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
Using SDCM from a Remote Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Remote Workstation Minimum Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Install SDCM Client on a Remote Workstation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Launch SDCM from the Remote Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Using the Network View Management Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
Accessing the Network View Management Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
Launching EWS from Network View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Launching SDCM from Network View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Chapter 3
Using EWS to Configure the Director
Launch EWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Configure Director Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Configure Director Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Configure Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Configure Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Configure Network Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Configure SNMP Trap Message Recipients. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Configure User Rights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Chapter 4
Backing up Configuration Data and Upgrading Firmware
Back up Configuration Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Record or Verify SDCM Server Restore Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Restoring the SDCM Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Manage Firmware Versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Determine a Director Firmware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Add a Firmware Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Modify a Firmware Version Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Delete a Firmware Version. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Download a Firmware Version to a Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Back Up the Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 411
Install or Upgrade Software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
Appendix A
Regulatory Compliance Notices
Regulatory Compliance ID Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A1
Federal Communications Commission Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Class A Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
Class B Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A2
vi SAN Director 64 Installation Guide
Declaration of Conformity for Products Marked
with FCC Logo United States Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A3
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Network and Serial Cables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Canadian Notice (Avis Canadien). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Class A Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Class B Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
European Union Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A4
Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A5
Laser Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6
Laser Safety Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6
Compliance with CDRH Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6
Compliance with International Regulations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6
Laser Product Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A6
Laser Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A7
Appendix B
Electrostatic Discharge
Precautions Against Electrostatic Discharge. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B1
Grounding Methods. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B2
Appendix C
Technical Specifications
Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Operating Tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Glossary
Index
Figures
Figure 11: Director components--front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 12: FPM card LEDs and connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Figure 13: Director components--rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Figure 21: Carton contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Figure 22: Securing shelf brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Figure 23: Securing the two mounting brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
Figure 24: Aligning the switch in the rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
Figure 25: Securing the rear angle brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Figure 26: AC power connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
Figure 27: Connecting the null modem cable between the Director and a workstation . . . . . . . 217
Figure 28: HyperTerminal configuration window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 219
Figure 29: LAN-connect the Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
Figure 210: SDCM Server Hardware Kit Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Figure 211: Removing the rail extensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
Figure 212: Positioning the server shelf kit in the rack. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Figure 213: Computer name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
Figure 214: Identification changes dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
Figure 215: Protocols tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
Figure 216: TCP/IP properties dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
Figure 217: DNS tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
Figure 218: TCP/IP DNS server dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
Figure 219: Date/Time properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
Figure 220: Time zone page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Figure 221: SDCM Manager login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235
Figure 222: Product View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
Figure 223: Configure Users dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Figure 224: New User dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Figure 225: New Product dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Figure 226: Hardware View (with FRU failures) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
Figure 227: Configure Date and Time dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
Figure 228: Configure Identification dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
viii SAN Director 64 Installation Guide
Figure 229: Configure Operating Mode dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Figure 230: Configure Operating Parameters dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Figure 231: Configure Ports check boxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
Figure 232: Configure SNMP dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
Figure 233: UDP Port Number column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Figure 234: Configure E-Mail dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
Figure 235: Test Remote Notification dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Figure 236: Connect the Fibre Channel cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Figure 237: Port Properties dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Figure 238: SDCM remote client install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
Figure 239: Open SAN Manager window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
Figure 240: Network View, SAN Topology screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
Figure 241: Switch Properties window. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
Figure 31: Enter Network Password dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Figure 32: View panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Figure 33: Configure ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Figure 34: Configure Director, Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Figure 35: Configure Director, Date/Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Figure 36: Set the Director offline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Figure 37: Configure Director, Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Figure 38: Configure Director, Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Figure 39: Activate message box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
Figure 310: Configure SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
Figure 311: Configure User Rights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313
Figure 41: Firmware Library dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Figure 42: New Firmware Version dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 43: New Firmware Description dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Figure 44: Change the firmware version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 45: Modify Firmware Description dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Figure 46: Send Firmware confirmation box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
Figure 47: Backup and Restore Configuration dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
Figure 48: SDCM Installer window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
Tables
Table 1: Related Documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xi
Table 11: SAN Director 64 Optional Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 21: Shipping Carton Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Table 22: Director Operational States and Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
Table A1: Laser Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A7
Table C1: Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C1
Table C2: Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Table C3: Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
Table C4: Operating Tolerances. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C2
About This Guide
This guide is part of a documentation set that supports the SAN Director 64. It is intended
for use by trained service and installation representatives experienced with the Storage
Area Network (SAN) technology and Fibre Channel technology.
This guide provides information on installing, configuring, managing, and verifying
operation of the SAN Director 64. The SAN Director 64 switch connects storage devices,
hosts, and servers in a SAN. The Director is easily managed and configured to optimize
the performance of your SAN.
Related Documents
The Compaq StorageWorks documentation listed in Table 1 provides additional
information about the SAN Director 64.
Table 1: Related Documents
Document Title Part Number
Compaq StorageWorks SAN Director 64 Installation Guide (this guide) AA-RQZQA-TE
Compaq StorageWorks SAN Director 64 Release Notes AA-RQZRA-TE
Compaq SANworks Director Connectivity Manager User Guide AA-RPL7A-TE
Compaq SANworks SAN Director 64 Product Manager User Guide AA-RPL9A-TE
Compaq StorageWorks SAN Director 64 Planning Guide AA-RPLAA-TE
Compaq StorageWorks SAN Director 64 Service Manual AA-RPL8A-TE
Compaq 9000 Series Rack Products Reference Guide 142553-002
Compaq StorageWorks SAN Director 64 Fibre Port Module Kit AA-RQZNA-TE
Installation Instructions
Compaq StorageWorks SAN Director 64 SDCM Hardware Kit AA-RR26A-TE
Installation Instructions
Compaq M-Series Rack Installation Instructions AA-RQZPA-TE
xii SAN Director 64 Installation Guide
Text Conventions
This document uses the following conventions to distinguish elements of text.
Keys Keys appear in boldface. A plus sign (+) between two
keys indicates that they should be pressed simultaneously.
USER INPUT User input appears in a different typeface and in
uppercase
FILENAMES File names appear in italic, initial capital letters except
when case-sensitive.
Menu Options, These elements appear in initial capital letters.
Command Names,
Dialog Box Names
COMMANDS, These elements appear in upper case.
DIRECTORY NAMES,
NOTE: UNIX commands are case sensitive and will not
and DRIVE NAMES appear in uppercase.
Type When you are instructed to type information, type the
information without pressing the Enter key.
Enter When you are instructed to enter information, type the
information and then press the Enter key.
About This Guide x iii
Symbols in Text
These symbols may be found in the text of this guide.
WARNING: Text set off in this manner indicates that failure to follow directions in the
warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions could
result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of
information.
Symbols on Equipment
These icons may be located on equipment in areas where hazardous conditions may exist.
Any surface or area of the equipment marked with these symbols indicates
the presence of electrical shock hazards. Enclosed area contains no
operator serviceable parts.
WARNING: To reduce the risk of injury from electrical shock hazards, do not
open this enclosure.
Any RJ-45 receptacle marked with these symbols indicates a Network
Interface Connection.
WARNING: To reduce the risk of electrical shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors into
this receptacle.
xiv SAN Director 64 Installation Guide
Any surface or area of the equipment marked with these symbols indicates
the presence of a hot surface or hot component. If this surface is contacted,
the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the
surface to cool before touching.
Power supplies or systems marked with these symbols indicate the
equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electrical shock,
remove all power cords to completely disconnect power from the
system.
Any product or assembly marked with these symbols indicates that the
component exceeds the recommended weight for one individual to handle
safely.
WARNING: To reduce the risk of personal INJURY or damage to the
equipment, observe local occupational health and safety requirements and
guidelines for manual material handling.
Rack Stability
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure
that:
s The leveling jacks are extended to the floor.
s The full weight of the rack rests on the leveling jacks.
s The stabilizing feet are attached to the rack if it is a single rack installation.
s The racks are coupled together in multiple rack installations.
s Only one component is extended at a time. A rack may become unstable if more
than one component is extended for any reason.
s Heaviest components are installed at the bottom of the rack.
About This Guide xv
Getting Help
If you have a problem and have exhausted the information in this guide, you can get
further information and other help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week.
NOTE: For continuous quality improvement, calls may be recorded or monitored.
Outside North America, call the nearest Compaq Technical Support Phone Center.
Telephone numbers for world wide Technical Support Centers are listed on the Compaq
Website. Access the Compaq Website by logging on to the Internet at
http://www.compaq.com.
Be sure to have the following information available before you call Compaq:
s Technical support registration number (if applicable)
s Product serial numbers
s Product model names and numbers
s Applicable error messages
s Add-on boards or hardware
s Third-party hardware or software
s Operating system type and revision level
s Detailed, specific questions
xvi SAN Director 64 Installation Guide
Compaq Website
The Compaq website has the latest information on this product as well as the latest drivers,
http://www.compaq.com.
Compaq Authorized Reseller
For the name of your nearest Compaq Authorized Reseller:
s In the United States, call 1-800-345-1518.
s In Canada, call 1-800-263-5868.
s Elsewhere, see the Compaq Website for locations and telephone numbers.
1
Chapter
Over view
This chapter contains the following information.
s SAN Director 64 Features
s SAN Director 64 Hardware Components
s SAN Director 64 Optional Kits
SAN Director 64 Features
Features of the SAN Director 64 include:
s Scalable from 32 to 64 User ports (with optional 64 Port Upgrade Kit)
s 100% dynamic non-blocking, cut through switching with congestion queuing
s Online error detection, error isolation, and error recovery
s Redundant hot-swap components
s Full duplex 100 MB/second per port performance
s Less than 2 s average switch latency
s 100 km distance support (60 buffers), with use of repeaters
s Small form factor, hot pluggable optical transceivers, auto configure G-ports
s Combination short-wave or long-wave laser transceivers
s Redundant power supplies and fan modules
s Online product repair for Field Replaceable Units (FRUs)
s Periodic health check and enhanced system monitoring
s Non-disruptive firmware load and update.
12 SAN Director 64 Installation Guide
SAN Director 64 Hardware Components
The Director provides a modular design that enables quick removal and replacement of
FRUs. The following sections define SAN Director 64 main components.
Front View
Figure 11 shows SAN Director 64 components accessible from the front of the Director.
Component descriptions follow the figure.
1 4
Power and System Error LEDs Cable Management Assembly
2 5
FPM Cards Front Bezel
3 6
Power Supplies CTP Cards
Figure 11: Director components--front
CTP Card
The Director ships with two Control Processor (CTP) cards. The active CTP card
initializes and configures the Director after power on, and contains the microprocessor and
associated logic that coordinate Director operation. The second CTP card serves as a
Overview 13
backup. A CTP card provides an Initial Machine Load (IML) button on the faceplate.
When the button is pressed and held for three seconds, the Director reloads firmware and
resets the CTP card without switching off power or affecting operational fibre-optic links.
Each CTP card also provides a 10/100 megabit per second (Mbps) RJ-45 twisted pair
connector on the faceplate that attaches to an Ethernet Local Area Network (LAN).
Each CTP card provides System Services Processor (SSP) and Embedded Port (EP)
subsystems. The SSP subsystem runs Director applications and the underlying operating
system, communicates with Director ports, and controls the RS-232 maintenance port and
10/100 Mbps Ethernet port. The EP subsystem provides Class F processing, and manages
frame transmission to and from the Serial Crossbar Assembly (SBAR). In addition, CTP
cards provide non-volatile memory for storing firmware.
Each card faceplate contains a green light emitting diode (LED) that lights if the card is
operational and active, and an amber LED that lights if the card fails. The LED is not lit on
the backup CTP.
Front Bezel
The bezel at the top front of the Director includes two indicator LEDs. The green power
LED lights when the Director is powered on and operational. If the LED turns off, a
facility power source, alternating current (AC) power cord, or Director power distribution
failure is indicated.
The amber system error LED lights when the Director detects an event requiring
immediate operator attention, such as a FRU failure. The LED remains illuminated as long
as an event is active. The LED blinks if unit beaconing is enabled.
Cable Management Assembly
The cable management assembly positioned at the front of the Director provides routing
for Ethernet cables attached to CTP cards and fibre-optic cables attached to Director ports.
The assembly rotates up to provide front access to the redundant power supplies.
14 SAN Director 64 Installation Guide
Power Supplies
The Director uses redundant, load-sharing power supplies which step down and rectify
facility input power to provide 48-Volt Direct Current (VDC) power to Director FRUs.
The power supplies also provide over-voltage and over-current protection. Either power
supply can be replaced while the Director is powered on and operational. Each power
supply has a separate backplane connection to allow for different AC power sources.
The power supplies are input rated at 85 to 264 volts alternating current (VAC). The
faceplate of each power supply provides the following status LEDs.
s A green PWR OK LED lights if the power supply is operational and receiving AC
power.
s An amber FAULT LED lights if the power supply fails.
s An amber TEMP LED lights if the power supply shuts down due to an over
temperature condition.
s An amber I LIM LED lights if the power supply is overloaded and operating at the
current limit (15.6 amperes).
Power supply requirements are listed in Appendix C, "Technical Specifications."
FPM Card
Each Fibre Port Module (FPM) card provides four full-duplex generic ports (G_Ports) that
transmit or receive data at 1.0625 gigabits per second (Gbps). G_Port functionality
depends on the type of cable attachment. FPM cards use Non-Open Fibre Control (NOFC)
Class 1 laser transceivers that comply with Section 21 of the Code of Federal Regulations
(CFR), Subpart (J) as of the date of manufacture.
Depending on device connections, G_Ports work as follows.
s If the G_Port is attached to a Fibre Channel device, the port functions as a fabric port
(F_Port). An F_Port is the interface on a Director that connects to a device N_Port.
s If the G_Port is attached to another Director to form an Interswitch Link (ISL), the port
functions as an expansion port (E_Port). A multi-switch fabric is formed through
multiple Directors and ISLs.
Figure 12 shows the faceplate of an FPM.
Overview 15
1 Card LED
2 Port LEDs
3 Port Connectors (G_Ports)
Figure 12: FPM card LEDs and connectors
Single-mode or multi-mode fibre-optic cables attach to FPM cards through small form
factor (SFF) pluggable optic transceivers. The fibre-optic transceivers provide duplex
connectors, and can be detached from FPM cards (through a 10-pin interface) for easy
replacement. Two fibre-optic transceiver types are available.
s Short-wave Laser--Short-wave laser transceivers provide connections for transferring
data over short distances (2 to 500 meters) through 50-micron (500 meters) or
62.5-micron (200 meters) multi-mode fibre.
s Long-wave Laser--Long-wave laser transceivers provide connections for transferring
data over long distances (up to 20 kilometers) through 9-micron single-mode fibre.
NOTE: Compaq recommends 50 micron fiber optic cable for any new installation requiring
multi-mode fiber.
16 SAN Director 64 Installation Guide
Rear View
Figure 13 shows the components accessible from the rear of the Director.
3
2
1
SHR-2309
1 Power module assembly
2 SBAR assemblies
3 Fan modules
Figure 13: Director components--rear
Fan Modules
Two fan modules, each containing three fans (six fans total), provide cooling for Director
FRUs, as well as redundancy for continued operation if a fan fails.
The fan module can be replaced while the Director is powered on and operating, provided
the module is replaced within ten minutes (after which software powers off the Director).
An amber LED for each fan module lights if one or more fans fail or rotate at insufficient
velocity.
Overview 17
SBAR Assembly
The Director ships with two SBAR assemblies. The active SBAR is responsible for Fibre
Channel frame transmission from any Director port to any other Director port.
Connections are established without software intervention. The assembly accepts a
connection request from a port, determines if a connection can be established, and
establishes the connection if the destination port is available. The assembly also stores
busy, source connection, and error status for each Director port.
The backup SBAR takes over operation if the active assembly fails, and provides the
ability to maintain connectivity and data frame transmission without interruption. The
transition to the backup assembly is transparent to attached devices.
Each SBAR assembly consists of a card and steel carriage that mounts flush on the
backplane. The carriage provides protection for the back of the card, distributes cooling
airflow, and assists in aligning the assembly during installation. The rear of the carriage
contains a green LED that lights if the assembly is operational and active, and an amber
LED that lights if the assembly fails. The amber LED blinks if FRU beaconing is enabled.
Power Module Assembly
The power module assembly is located at the bottom rear of the Director. The module
provides the following.
s Two single-phase AC power connectors. Each connector is input rated at 85 to 264
VAC.
s A power switch (circuit breaker) that controls AC power distribution to both power
supplies. The breaker is set manually, or is automatically tripped by internal software if
thermal sensors indicate the Director is overheated.
s A 9-pin maintenance port that provides a connection for a local terminal or dial-in
connection for a remote terminal.
18 SAN Director 64 Installation Guide
SAN Director 64 Optional Kits
Contact your Compaq Sales Representative to purchase the following optional SAN
Director 64 kits. See Table 11.
Table 11: SAN Director 64 Optional Kits
Supporting Kit Description
The SDCM Manager Kit consists of a laptop
SANworks Director Connectivity
computer, pre-loaded with SDCM software. Also
Manager Kit, and SANworks Director
includes all the necessary hardware components
Connectivity Software Kit,
(pre-assembled on an adjustable rack-mount
Part Number: DS-DMGG0-AA (these
shelf) required to run SDCM.
products ship together)
The SDCM Software Kit includes the SDCM Server
Restore/Boot CD, SDCM Management Applications
CD, SDCM Software License Agreement, and
Warranty.
Long-wave Port Module Kit, Provides additional long-wave ports
Part Number: DS-DMGGD-AC for the Director.
Short-wave Port Module Kit, Provides additional short-wave ports
Part Number: DS-DMGGD-AD for the Director.
Provides three additional long-wave and one
Combination Long-wave/Short-wave
additional short-wave port for the Director.
Port Module Kit,
Part Number: DS-DMGGD-AE
M-Series Rack Mount Kit, Provides cabinet, mounting hardware and
Part Number: DS-DMGGD-AF installation instructions.
2
Chapter
Installing and Configuring the SAN Director 64
This chapter contains the following information.
s Lists installation requirements
s Provides a carton contents checklist
s Outlines how to install the Director in a Compaq 9000 Series, or comparable rack
s Describes how to configure the Director
s Summarizes SAN Director Connectivity Manager (SDCM) Server set up and
configuration.
Review Installation Requirements
WARNING: The SAN Director 64 weighs approximately 115 pounds. Use proper
handling and lifting equipment to reduce the possibility of injury or product damage.
The Director is delivered stand-alone and ready to be mounted in a Compaq 19-inch
equipment rack. Rack mount brackets and hardware are provided in the shipping
container. Ethernet cabling, distance, and LAN addressing issues must be considered.
Review the following checklist before installing the switch.
s Prepare a site plan. Consult the Compaq StorageWorks SAN Director 64 Planning Guide, Part
Number AA-RPLAA-TE.
s Verify that required technical personnel are available and scheduled for the
installation.
22 SAN Director 64 Installation Guide
s Obtain the required fibre-optic cables (multi-mode or single-mode). Verify cable
length and required connectors.
s Obtain a Compaq 19-inch equipment rack.
s If applicable, obtain the necessary remote workstations or Simple Network
Management Protocol (SNMP) workstations. Workstations are customer-supplied and
connected through a corporate or dedicated LAN.
s Verify that the front panel air temperature does not exceed 40 C (104 F) during
operation.
s Verify that there is space in the rack. The Director is 9U, or 15.75 inches high.
s Verify that the rack is stable.
s Verify that all other equipment installed in the rack is connected to a reliable ground
connection; do not rely on connections to a branch circuit, such as a power strip.
s Compaq recommends securing the rack mechanically to prevent it from tipping over
during a natural disaster, such as an earthquake.
Items Required for Installation
Locate the following items before beginning the install procedure.
s Lift device (recommended)
s SAN Director 64
s A Compaq 9000 Series Rack, Compaq M Series Rack, or any rack with the following
specifications,
a minimum depth of 24.5-inches
9 rack units (9U) high
19-inches wide.
s Two power outlets (for redundancy)
s Torque driver with cross-tip bit (for setting 22 in.- lbs. of torque)
s Fibre-optic protective plug--For safety and port transceiver protection, fibre-optic
protective plugs must be inserted in all Director ports without fibre-optic cables
attached. The Director is shipped with protective plugs installed in all ports.
s Null modem cable--An asynchronous RS-232 null modem cable is required to
configure Director network addresses and obtain event log information through the
maintenance port. The cable has nine conductors and two DB-9 female connectors.
Installing and Configuring the SAN Director 64 23
s Standard flat-tip and cross-tip Phillips screwdrivers--Required to remove, replace,
adjust or tighten various FRUs, chassis, or cabinet components.
s Electrostatic discharge (ESD) grounding cable with attached wrist strap--Required
when working in and around the Director card cage.
s Maintenance terminal (desktop or notebook computer)-- Required to configure
Director network addresses and acquire event log information through the
maintenance port. Computer requirements include:
Microsoft Windows 98, Windows NT 4.0, Windows 2000, or Windows
Millennium Edition operating system installed
RS-232 serial communication software (for example, ProComm Plus or
HyperTerminal).
Select an Operating Location
Install the Director in a secure or limited-access area to ensure that cable connections are
not compromised. Also, make sure to install the Director in an area with the ventilation
and power requirements described next.
Cooling and Power Requirements
Two fan modules, each containing three fans (six fans total), provide cooling for the
Director, as well as redundancy if a fan fails. The air intake for the Director must satisfy an
operating environment temperature requirement of 40F to 104F (4C to 40C).
Director power requirements are listed next.
s Input voltage: 100 to 120 or 200 to 240 VAC
s Input frequency: 50/60 Hz
CAUTION: Do not block Director air vents. The switch uses ambient air for cooling.
24 SAN Director 64 Installation Guide
Unpack and Inspect the Director
Unpack and inspect the Director as follows.
1. Inspect the shipping container for damage caused during transit.
2. Unpack the shipping cartons.
3. Verify that the carton contains the items shown in Figure 21 and Table 21.
IMPORTANT: If any items are damaged or missing, please contact Compaq
or a Compaq Authorized Reseller.
Installing and Configuring the SAN Director 64 25
s.
Figure 21: Carton contents
26 SAN Director 64 Installation Guide
Table 21: Shipping Carton Contents
Number Item
1 One SAN Director 64 Product CD containing firmware, license,
documentation
2 SAN Director 64 Installation Guide, SAN Director 64 Release Notes
3 Two Power Distribution Unit (PDU) Power cords
4 Two standard AC Power Cords
5 Four multi-mode, short-wave loopback plugs
6 One torque driver with integrated 5/32" bit
7 One 10-foot null modem cable
8 Compaq 9000 Series Rack Mount Kit containing:
Two Front Mounting Brackets
Two Rear Mounting Plates
Two Rear Angle Brackets
9 Two Shelf Brackets
10 Pouch containing Compaq 9000 Series Rack Mount hardware:
Eight 10-32 x 0.375 in. Phillips panhead screws--Installs two shelf
brackets to rails
Six 10-32 x 0.375 in. Phillips panhead screws--Installs two front
mounting brackets to rails.
Four 10-32 X 0.25 in. Phillips countersunk screws--Installs front
brackets to switch.
Ten 10-32 cage nuts--Secures front and rear shelf brackets.
Four 0-32 x 0.375 in. Phillips panhead screws--Installs rear bracket
sections.
Four 10-32 X 0.25 in. Phillips countersunk screws--Installs rear
mounting plates to chassis.
Four 10-32 X 0.375 in. Phillips panhead screws--Installs two rear angle
brackets.
Eight square alignment washers
11 One Cable Management Assembly
12 Compaq SAN Director 64
Installing and Configuring the SAN Director 64 27
Install the Director in a 9000 Series Rack
NOTE: The Director ships with the complete set of rack mount hardware required for
installation in the Compaq 9000 Series Rack. If you plan to install the Director in the optional
Compaq M-Series Rack, Part Number DS-DMGGD-AF, consult the Compaq M Series Rack
Mount Kit Installation Guide., Part Number AA-RQZPA-TE.
Obtain the following tools.
s A #2 Phillips screwdriver
s Torque screwdriver.
Tips for Installing More than One Switch
Review the following tips.
s Install the first Director in the lowest position of the rack, allocated for switches.
s If installing more than one switch, Compaq recommends installing an optional PDU in
the bottom of the rack. Compaq ships two PDU power cords with the Director.
s Install additional Directors in position directly above one another.
s Make sure to connect power cables as you install each individual switch.
Transfer the Director to the Lift Device
Use these steps to position the Director next to the rack.
WARNING: Two people will need to work together to transfer the Director to the lift.
Make sure the wheels of the lift cannot roll as you transfer the Director to the lift.
Move the Director slowly and carefully onto the lift to prevent back and hand injury.
Dropping the Director could injure personnel or damage the equipment.
1. Position the lift device next to the Director.
2. Using a pallet jack, raise the pallet on which the Director is mounted to the same
height as the top surface of the lift device.
3. Slide the Director across from the pallet to the lift device.
4. Determine the appropriate rack-mount position. Remember that the Director is 15.75
inches or 9 U high.
28 SAN Director 64 Installation Guide
Install the Shelf Brackets in the 9000 Series Rack
Use these steps to install the two shelf brackets in the rack.
1. Determine the appropriate placement for the switch inside the rack. It is important to
consider the number of switches you intend to install. See "Tips for Installing More
than One Switch," listed previously in this chapter.
2. Locate the small, round marker hole on the rails that coincides with the location
selected in step1. Each marker hole delineates the beginning of one rail unit, or U.
3. Locate the square opening in the rail that corresponds with the appropriate marker
hole. See Figure 22.
1 3
Marker hole Screws with captive lock and flat washers
2 4
Square opening in rail Square alignment washers
Figure 22: Securing shelf brackets
Installing and Configuring the SAN Director 64 29
NOTE: Consider leaving the bottom and top U positions open to permit easy accessibility to the
cables entering and exiting the cabinet.
4. Position the higher, shelf bracket threaded hole in this square opening. See Figure 22.
5. Orient the shelf bracket in the rails.
6. Insert the square washer provided in the rail square hole.
7. Insert the panhead Phillips screw, and partially tighten to temporarily stabilize the
bracket.
8. Make sure the shelf bracket is level, and align the rear of the shelf bracket with the
appropriate position on the rear rail See Figure 22.
9. Repeat steps 4 through 7 for the rear end of the shelf bracket.
10. Repeat steps 1 through 9 for the second shelf bracket.
11. Completely tighten all screws attaching shelf brackets to the rack's rails.
12. Using a torque driver, torque the screws to 22 in.- lbs.
Prepare the Switch for Install
The following section describes how to install the mounting hardware that attaches the
switch to the rails. This hardware includes,
s Two front mounting brackets
s Two rear mounting plates
s Ten cage nuts
s Eight screws.
210 SAN Director 64 Installation Guide
Secure the Mounting Hardware
Use these steps to secure the mounting hardware to the switch.
1. Locate the two front mounting brackets in the shipping carton.
2. Secure the front mounting brackets on either side of the switch as shown in Figure 23.
For each front mounting bracket, use two flathead countersunk Phillips screws (10/32
x 0.25-inch) provided.
Figure 23: Securing the two mounting brackets
3. Using a torque driver, torque the screws to 22 in.- lbs.
4. Locate the two rear mounting plates in the shipping carton.
5. Secure the two rear mounting plates to each side of the switch as shown in Figure 23.
For each plate, use two flathead countersunk Phillips screws (10/32 x 0.25-inch)
provided.
6. Using a torque driver, torque the screws to 22 in.- lbs.
Installing and Configuring the SAN Director 64 211
Insert the Cage Nuts
Read the following sections for instructions on inserting front and rear cage nuts in the
rack.
Insert the Front Cage Nuts in the Rack
Use these steps to insert the six supplied cage nuts in the rack's front rails.
1. Select one of the front rails. Count up 11 square openings from the top screw of the
shelf bracket, and insert the first of three cage nuts.
2. Count up 5 square openings from the cage nut you just installed, and insert the next
cage nut.
3. Count up four square openings for the third cage nut.
4. To install cage nuts in the corresponding front rail, repeat step 1 through step 3.
Insert the Rear Cage Nuts in the Rack
Use these steps to insert the four supplied cage nuts in the rack's rear rails.
1. Select one of the rear rails, and count up six square openings from the top screw of the
rear shelf bracket. Insert the first of two cage nuts.
2. Count up sixteen square openings from the cage nut you just installed, and insert the
next cage nut.
3. To install cage nuts in the rack's corresponding rear rail, repeat step 1 through step 2.
Finalize the Rack Mounting Procedure
Read the following sections to complete the installation procedure.
After completing the steps outlined in the previous section, prepare to orient the Director
in the rack, as follows. The procedure requires two technicians.
CAUTION: The Director weighs approximately 115 lbs. Do not attempt to lift or carry
the Director with fewer than two people. Failure to observe this CAUTION may result in
injury to personnel or damage to the Director.
212 SAN Director 64 Installation Guide
1. Carefully lift the switch into the front of the cabinet and onto the shelf brackets. Slide
the switch forward into the rack until the edge of the rear mounting plates are
approximately 1-inch from the rack's rails. See Figure 24.
Figure 24: Aligning the switch in the rack
2. Align one rear angle bracket with the cage nuts installed earlier, see "Inserting Cage
Nuts." See Figure 25.
NOTE: Make sure that the angle bracket is in contact with the outside surface of the
mounting plate.
3. Loosely attach the rear angle bracket to the rack rail with the two panhead Phillips
screws provided. See Figure 25.
Installing and Configuring the SAN Director 64 213
4. Repeat steps 2 and 3 for the corresponding rear angle bracket. See Figure 25.
Figure 25: Securing the rear angle brackets
5. The two rear angle brackets now touch the outside surfaces of the rear mounting plates.
Slide the Director all the way into the rack to where the front mounting bracket meets
the rack rails.
6. If you are certain that the hardware lines up properly, secure the hardware as follows.
142553-002
AA-RP8AB-TE
AA-RPL7A-TE
AA-RPL8A-TE
AA-RPL9A-TE
AA-RPLAA-TE
AA-RQZNA-TE
AA-RQZPA-TE
AA-RQZQA-TE
AA-RQZRA-TE
AA-RR26A-TE
DS-DMGG0-AA
DS-DMGGD-AC
DS-DMGGD-AD
DS-DMGGD-AE
DS-DMGGD-AF
Page 1 - Page 2 - Page 3 - Page 4 -