Product Details

Compaq StorageWorks
M-Series Rack Mount Kit
Installation Instructions
First Edition (September 2001)
Part Number: AA-RQZPA-TE
Compaq Computer Corporation
2001 Compaq Computer Corporation.
Compaq, the Compaq logo, and StorageWorks Registered in U. S. Patent and Trademark Office.
All other product names mentioned herein may be trademarks of their respective companies.
Confidential computer software. Valid license from Compaq required for possession, use or copying.
Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software
Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under
vendor's standard commercial license.
Compaq shall not be liable for technical or editorial errors or omissions contained herein. The
information in this document is provided "as is" without warranty of any kind and is subject to change
without notice. The warranties for Compaq products are set forth in the express limited warranty
statements accompanying such products. Nothing herein should be construed as constituting an additional
warranty.
Compaq service tool software, including associated documentation, is the property of and contains
confidential technology of Compaq Computer Corporation. Service customer is hereby licensed to use
the software only for activities directly relating to the delivery of, and only during the term of, the
applicable services delivered by Compaq or its authorized service provider. Customer may not modify or
reverse engineer, remove, or transfer the software or make the software or any resultant diagnosis or
system management data available to other parties without Compaq's or its authorized service provider's
consent. Upon termination of the services, customer will, at Compaq's or its service provider's option,
destroy or return the software and associated documentation in its possession.
Printed in the U.S.A.
M-Series Rack Mount Kit
Installation Instructions
First Edition (September 2001)
Part Number: AA-RQZPA-TE
Contents
About This Guide
Symbols in Text . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v
Symbols on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi
Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Compaq Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Compaq Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Compaq Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
M-Series Rack Mount Kit Installation
Preparing for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Required Items . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Tips for Installing More than One Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Moving the Director . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installing the Shelf Brackets in the M-Series Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Mounting Hardware to the Director. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Inserting Cage Nuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Insert the Front Cage Nuts in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Insert the Rear Cage Nuts in the Rack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Finalizing the Rack Mounting Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power-On Self Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Further Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
About This Guide
This guide is designed to be used as a reference for installation.
Symbols in Text
These symbols may be found in the text of this guide. They have the following meanings.
WARNING: Text set off in this manner indicates that failure to follow directions in the
warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions could
result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points of
information.
vi M-Series Rack Mount Kit Installation Instructions
Symbols on Equipment
These icons may be located on equipment in areas where hazardous conditions may exist.
Any surface or area of the equipment marked with these symbols indicates
the presence of electrical shock hazards. Enclosed area contains no
operator serviceable parts.
WARNING: To reduce the risk of injury from electrical shock hazards, do not
open this enclosure.
Any RJ-45 receptacle marked with these symbols indicates a Network
Interface Connection.
WARNING: To reduce the risk of electrical shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors into
this receptacle.
Any surface or area of the equipment marked with these symbols indicates
the presence of a hot surface or hot component. If this surface is contacted,
the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow the
surface to cool before touching.
Power Supplies or Systems marked with these symbols indicate the
equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electrical shock,
remove all power cords to completely disconnect power from the
system.
About This Guide vii
Any product or assembly marked with these symbols indicates that the
component exceeds the recommended weight for one individual to handle
safely.
WARNING: To reduce the risk of personal INJURY or damage to the
equipment, observe local occupational health and safety requirements and
guidelines for manual material handling.
Rack Stability
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure
that:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack if it is a single rack installations.
The racks are coupled together in multiple rack installations.
A rack may become unstable if more than one component is extended for any
reason. Extend only one component at a time.
Getting Help
If you have a problem and have exhausted the information in this guide, you can get
further information and other help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week.
NOTE: For continuous quality improvement, calls may be recorded or monitored.
Outside North America, call the nearest Compaq Technical Support Phone Center.
Telephone numbers for world wide Technical Support Centers are listed on the Compaq
website. Access the Compaq website by logging on to the Internet at
http://www.compaq.com.
Be sure to have the following information available before you call Compaq:
viii M-Series Rack Mount Kit Installation Instructions
Technical support registration number (if applicable)
Product serial numbers
Product model names and numbers
Applicable error messages
Add-on boards or hardware
Third-party hardware or software
Operating system type and revision level
Detailed, specific questions
Compaq Website
The Compaq website has latest information on this product as well as the latest drivers.
You can access the Compaq website by logging on to the Internet at
http://www.compaq.com/storage.
Compaq Authorized Reseller
For the name of your nearest Compaq Authorized Reseller:
In the United States, call 1-800-345-1518.
In Canada, call 1-800-263-5868.
Elsewhere, see the Compaq website for locations and telephone numbers.
M-Series Rack Mount Kit Installation
This section describes the procedures used for installing a SAN Director 64 (Director) in
an M-Series Rack, using the M-Series Rack Mount Kit (DS-DMGGD-AF).
Preparing for Installation
Kit Contents
Your M-Series Rack Mount Kit (DS-DMGGD-AF) should contain the following items:
Table 1 Contents of M-Series Rack Mount Kit
Number Item Quantity Quantity Required
1 Shelf Brackets 2 2
2 Front Mounting Brackets, left and right, flat 2 2
3 Rear Mounting Brackets, left and right, angle 2 2
4 Front Angle Brackets, left and right 2 2
5 Pouch containing Compaq M-Series Rack Mount hardware:
10-32 X 0.5 in Phillips panhead screws with lock washers--Shelf 22 20
and Angle Brackets to rails, also Front Mounting Brackets to Front
Angle Brackets
10-32 X 0.375 in Phillips flathead screws--Installs Front and 8 8
Rear Mounting Brackets to Director
10-32 cage nuts--Installs Front and Rear Angle Brackets to rail 10 8
Stainless Steel Washers, 0.191 in ID, 0.278 in OD, 0.032 in thick, 8 8
installs Shelf Brackets to rails
Square Alignment Washers (only used with 9000 Series rack) 10 0
2 M-Series Rack Mount Kit Installation Instructions
3
4
2
5
1
SHR-2319
Figure 1 M-Series Rack Mount Kit Contents
Required Items
SAN Director 64
M-Series Rack Mount Kit
Lift Device (recommended)
M-Series Rack
Torque driver with cross-tip bit (for setting screws with 22 in.-lbs. of torque)
#2 Phillips Screwdriver
M-Series Rack Mount Kit Installation 3
Tips for Installing More than One Switch
Review the following tips.
Install the first Director in the lowest position of the rack, allocated for switches.
Consider leaving a space of 1U open at the top and bottom of the rack, to allow easier
cabling access.
If installing more than one switch, Compaq recommends installing an optional Power
Distribution Unit (PDU) in the bottom of the rack. Compaq ships two PDU power
cords with the Director.
Install additional Directors in position directly above one another.
Make sure to connect power cables as you install each individual switch.
Moving the Director
Use these steps to position the Director next to the rack.
WARNING: Two people will need to work together to transfer the Director to the lift.
Make sure the wheels of the lift cannot roll as you transfer the Director to the lift.
Move the Director slowly and carefully onto the lift to prevent back and hand injury.
Dropping the Director could injure personnel or damage the equipment.
1. Position the lift device next to the Director.
2. Using a pallet jack, raise the pallet on which the Director is mounted to the same
height as the top surface of the lift device.
3. Slide the Director across from the pallet to the lift device.
4. Determine the appropriate rack-mount position. Remember that the Director is 15.75
inches or 9 U high.
4 M-Series Rack Mount Kit Installation Instructions
Installation
Installing the Shelf Brackets in the M-Series Rack
Use these steps to install the two shelf brackets in the rack.
1. Determine the appropriate placement for the switch inside the rack. It is important to
consider the number of switches you intend to install. See "Tips for Installing More
than One Switch," listed previously in this document.
2. Count the round openings in the rail to identify the required position for the switch.
Count three round openings for every rail unit, or U, along the rail.
3. Locate the round hole that corresponds with the required U position. See Figure 2.
1
2
3
SHR-2320
1 3
Rack Rail Washers and screw
2 Round opening in rail
Figure 2 Securing shelf brackets
M-Series Rack Mount Kit Installation 5
4. Position the higher, shelf bracket threaded hole in this round opening. See Figure 2.
5. Orient the shelf bracket in the rails.
6. Insert a small washer into the rail hole.
7. Insert a screw through the rail hole, the small washer in the hole, and up to the threaded
hole in the shelf bracket.
8. Partially tighten the screw to temporarily stabilize the shelf bracket.
9. Make sure the shelf bracket is level, and align the rear of the shelf bracket with the
appropriate position on the rear rail. See Figure 2.
10. Repeat steps 4 through 8 for the rear end of the shelf bracket.
11. Repeat steps 1 through 10 for the second shelf bracket.
12. Completely tighten all screws attaching shelf brackets to the rack rails. Torque the
screws to 22 in-lbs.
Attaching the Mounting Hardware to the Director
Use these steps to secure the mounting hardware to the switch.
NOTE: All mounting brackets are attached to the switch using 10/32 x 0.375-inch flathead
countersunk Phillips screws.
1. Locate the two front mounting brackets in the shipping carton.
2. Secure the front mounting brackets on either side of the switch as shown in Figure 3.
For each front mounting bracket, use two screws.
6 M-Series Rack Mount Kit Installation Instructions
Storage
Works
SAN 64
SHR-2321
Figure 3 Securing the front and rear mounting brackets
3. Using a torque driver, torque the screws to 22 in.- lbs.
4. Locate the two rear mounting brackets in the shipping carton.
5. Secure the two rear mounting brackets to each side of the switch as shown in Figure 3.
For each bracket, use two screws.
6. Using a torque driver, torque the screws to 22 in.- lbs.
Inserting Cage Nuts
Before placing the switch into the rack, insert the cage nuts into the appropriate locations
along the rack rails. Read the following sections for instructions on inserting front and rear
cage nuts in the rack.
Insert the Front Cage Nuts in the Rack
Use these steps to insert the four supplied cage nuts in the rack's front rails.
1. Select one of the front rails. Count up 11 round openings from the top screw of the
shelf bracket, and insert the first of four cage nuts.
M-Series Rack Mount Kit Installation 7
2. Count up 9 round openings from the cage nut you just installed, and insert the next
cage nut.
3. To install cage nuts in the companion front rail, repeat step 1 through step 2.
Insert the Rear Cage Nuts in the Rack
Use these steps to insert the four supplied cage nuts in the rack's rear rails.
1. Select one of the rear rails, and count up 6 round openings from the top screw of the
rear shelf bracket. Insert the first of four cage nuts.
2. Count up 16 round openings from the cage nut you just installed, and insert the next
cage nut.
3. To install cage nuts in the companion rear rail, repeat step 1 through step 2.
Finalizing the Rack Mounting Procedure
Read the following sections to complete the installation procedure.
After completing the steps outlined in the previous section, prepare to orient the Director
in the rack, as follows. The procedure requires two technicians.
CAUTION: The Director weighs approximately 115 lbs. Do not attempt to lift or carry
the Director with fewer than two people. Failure to observe this CAUTION may result in
injury to personnel or damage to the Director.
8 M-Series Rack Mount Kit Installation Instructions
1. Carefully lift the switch into the rear of the cabinet. Slide the switch forward until the
edge of the front mounting brackets are approximately 1-inch from the rack's rails. See
Figure 4.
SHR-2322
Figure 4 Aligning the switch in the rack.
2. Align one front angle bracket with the cage nuts installed earlier, see "Inserting Cage
Nuts." See Figure 5.
NOTE: Make sure that the angle bracket is in contact with the outside surface of the
mounting bracket on the switch. The angle bracket will be between the rail and mounting
bracket.
3. Loosely attach the front angle bracket to the rack rail with the two panhead Phillips
screws provided. See Figure 5.
M-Series Rack Mount Kit Installation 9
4. Repeat steps 2 and 3 for the corresponding front angle bracket. See Figure 5.
Storage
Works
SAN 64
SHR-2323
Figure 5 Securing the front angle brackets
5. The two front angle brackets now touch the outside surfaces of the front mounting
plates. Slide the Director all the way into the rack to where the rear mounting brackets
meets the rack rails.
CAUTION: Avoid placing fingers or tools near the front mounting brackets while
moving the switch. Objects can become pinched between the mounting brackets and
the angle brackets.
6. If you are certain that the hardware lines up properly, secure the hardware as follows.
a. Secure each front mounting plate to the front angle bracket with the two screws
provided.
b. Move to the rear of the switch, and secure each rear mounting bracket with the two
screws provided.
7. Using a a torque driver, torque the screws to 22 in. - lbs.
10 M-Series Rack Mount Kit Installation Instructions
8. Connect the remaining ends of the AC power cords to the PDU as shown in Figure 6. If
the optional second PDU is installed, then connect each power cord to a separate PDU.
NOTE: Compaq recommends installing an optional PDU in the rack. Compaq
ships two PDU power cords with the Director.
SHR-2273
Figure 6 AC power connections
WARNING: Compaq-supplied power cords are provided for each Director power
supply. To prevent electric shock, use only the supplied power cord(s). Also, verify that
the facility power receptacle is the correct type, supplies the required voltage, and is
properly grounded.
9. Connect the equipment rack power cords to separate (for redundancy) facility power
sources, providing single-phase, 120 to 240 VAC current.
Power-On Self Test
Use the following steps to run a Power-On Self Test (POST).
1. Power on the PDU (or PDUs if the optional one is installed).
2. At the bottom rear of the Director, set the power switch (circuit breaker) to the Up
position. The Director powers on. The following occurs during POST.
a. Amber LEDs on both CTP cards and all FPM cards illuminate momentarily.
b. The green LED on each CTP card (active and backup) lights as the card is tested
and FPM cards are tested.
M-Series Rack Mount Kit Installation 11
c. Green LEDs associated with Fibre Channel ports sequentially illuminate as the
ports are tested.
3. After successful POST completion, the green power LED on the front bezel, green
LED on the active CTP card, and green PWR OK LEDs on both power supplies
remain illuminated.
4. If a POST error or other malfunction occurs, refer to the "Maintenance Analysis
Procedures" section in the Compaq StorageWorks SAN Director 64 Service Manual.
Further Setup
For additional information on installing and configuring the Director , please see the
SAN Director 64 Installation Guide.
AA-RQZPA-TE
DS-DMGGD-AF
Page 1 -

3prime solutions for all your Digital requirements

     
 


HP is a registered trademark