Product Details

ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
First Edition (July 2000)
Part Number 189018-001
Compaq Computer Corporation
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
Notice
2000 Compaq Computer Corporation.
Compaq, NonStop, ProLiant, SmartStart, Compaq Insight Manager, and the Compaq logo Registered in
U. S. Patent and Trademark Office. ROMPaq is a trademark and/or service mark of Compaq
Information Technologies Group, L.P. Microsoft, MS-DOS, Windows, and Windows NT are trademarks
of Microsoft Corporation. Intel and Pentium are trademarks of Intel Corporation. UNIX is a trademark
of The Open Group. All other product names mentioned herein may be trademarks or registered
trademarks of their respective companies.
The information in this publication is subject to change without notice and is provided "AS IS"
WITHOUT WARRANTY OF ANY KIND. THE ENTIRE RISK ARISING OUT OF THE USE OF
THIS INFORMATION REMAINS WITH RECIPIENT. IN NO EVENT SHALL COMPAQ BE
LIABLE FOR ANY DIRECT, CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR
OTHER DAMAGES WHATSOEVER (INCLUDING WITHOUT LIMITATION, DAMAGES FOR
LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION OR LOSS OF BUSINESS
INFORMATION), EVEN IF COMPAQ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
The limited warranties for Compaq products are exclusively set forth in the documentation
accompanying such products. Nothing herein should be construed as constituting a further or additional
warranty.
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
First Edition (July 2000)
Part Number 189018-001
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
Contents
About This Guide
Text Conventions.......................................................................................................vii
Symbols in Text....................................................................................................... viii
Symbols on Equipment............................................................................................ viii
Getting Help ................................................................................................................ x
Compaq Technical Support .................................................................................. x
Compaq Website...................................................................................................x
Compaq Authorized Reseller...............................................................................xi
Chapter 1
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Clustering Overview
Overview of Compaq ProLiant Clusters for UnixWare 7........................................ 1-1
Cluster Configuration .............................................................................................. 1-2
Compaq ProLiant ML330 Servers ........................................................................... 1-4
Cluster Interconnect................................................................................................. 1-5
Ethernet Crossover Cable ................................................................................. 1-5
Cluster Integrity Serial Cable .................................................................................. 1-5
LAN Connection...................................................................................................... 1-6
SCO UnixWare Software......................................................................................... 1-6
Compaq Software .................................................................................................... 1-7
Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs ............... 1-7
Compaq SmartStart and Support Software CD ................................................ 1-8
Compaq Management CD ................................................................................ 1-8
Resources for Application Installation..................................................................... 1-9
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
iv Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Chapter 2
Setting Up Hardware for the Compaq ProLiant Clusters for SCO UnixWare 7
U/ML330
Setting Up Components ........................................................................................... 2-1
Setting Up the Nodes ........................................................................................ 2-2
Cabling the Components.......................................................................................... 2-2
Using Labeling Standards ................................................................................. 2-3
Cabling the Ethernet Crossover Cable .............................................................. 2-3
Cabling the Cluster Integrity Serial Cable ........................................................ 2-4
Cabling the Keyboard, Monitor, and Mouse..................................................... 2-4
Chapter 3
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7
U/ML330
Preinstallation Tasks and Considerations................................................................. 3-2
Obtaining UnixWare 7 Licenses .............................................................................. 3-2
Configuring the Servers with SmartStart ................................................................. 3-3
Installing the Cluster with Quick Install .................................................................. 3-4
Installing the First Node.................................................................................... 3-5
Installing the Second Node ............................................................................... 3-7
Verifying Cluster Assembly and Installation ........................................................... 3-8
Registering the Compaq ProLiant Cluster for SCO UnixWare 7............................. 3-8
Chapter 4
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330
TM
SCO UnixWare 7 NonStop Clusters Management Software ................................ 4-2
Clusterized SCOadmin...................................................................................... 4-2
Event Processing Subsystem............................................................................. 4-3
TM
NonStop Clusters Management Subsystem ................................................... 4-3
SCO Clusterized Commands ............................................................................ 4-4
Compaq ProLiant Cluster Management Software for SCO UnixWare 7
TM
NonStop Clusters .................................................................................................. 4-6
Compaq Insight Manager Support .................................................................... 4-6
Compaq Insight Manager XE Support.............................................................. 4-7
UPS-Initiated Shutdown, Configuration, and Setup ......................................... 4-8
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
Contents v
Chapter 5
Troubleshooting Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330
Installation Problems ............................................................................................... 5-2
Quick Install Error Messages............................................................................ 5-3
Node-to-Node Communication Problems ........................................................ 5-4
Client-to-Cluster Connectivity Problems.......................................................... 5-5
Cluster Resource Problems............................................................................... 5-6
Appendix A
Software Versions
Appendix B
Quick Install Planning Worksheets
Glossary
Index
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
About This Guide
This guide is designed to be used as step-by-step instructions for installation
and as a reference for operation and troubleshooting.
Text Conventions
This document uses the following conventions to distinguish elements of text:
Keys Keys appear in boldface. A plus sign (+) between
two keys indicates that they should be pressed
simultaneously.
User Input and Commands User input and commands appear in a different
typeface.
File names, directory File names appear in lowercase.
names, and drive names
Menu Options, Dialog These elements appear in initial capital letters.
Box Names
Type When you are instructed to type information, type
the information without pressing the Enter key.
Enter When you are instructed to enter information, type
the information and then press the Enter key.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
viii Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Symbols in Text
These symbols may be found in the text of this guide. They have the following
meanings.
WARNING: Text set off in this manner indicates that failure to follow directions
in the warning could result in bodily harm or loss of life.
CAUTION: Text set off in this manner indicates that failure to follow directions
could result in damage to equipment or loss of information.
IMPORTANT: Text set off in this manner presents clarifying information or specific
instructions.
NOTE: Text set off in this manner presents commentary, sidelights, or interesting points
of information.
Symbols on Equipment
These symbols may be located on equipment in areas where hazardous
conditions may exist.
This symbol in conjunction with any of the following symbols indicates the
presence of a potential hazard. The potential for injury exists if warnings
are not observed. Consult your documentation for specific details.
This symbol indicates the presence of hazardous energy circuits or
electric shock hazards. Refer all servicing to qualified personnel.
WARNING: To reduce the risk of injury from electric shock hazards, do
not open this enclosure. Refer all maintenance, upgrades, and
servicing to qualified personnel.
This symbol indicates the presence of electric shock hazards. The area
contains no user or field serviceable parts. Do not open for any reason.
WARNING: To reduce the risk of injury from electric shock hazards,
do not open this enclosure.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
About This Guide ix
This symbol on an RJ-45 receptacle indicates a Network Interface
Connection.
WARNING: To reduce the risk of electric shock, fire, or damage to the
equipment, do not plug telephone or telecommunications connectors
into this receptacle.
This symbol indicates the presence of a hot surface or hot component.
If this surface is contacted, the potential for injury exists.
WARNING: To reduce the risk of injury from a hot component, allow
the surface to cool before touching.
These symbols on power supplies or systems indicate that the
equipment is supplied by multiple sources of power.
WARNING: To reduce the risk of injury from electric shock,
remove all power cords to completely disconnect power from
the system.
This symbol indicates that the component exceeds the
recommended weight for one individual to handle safely.
WARNING: To reduce the risk of personal injury or damage to the
equipment, observe local occupational health and safety
requirements and guidelines for manual material handling.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
x Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Getting Help
If you have a problem and have exhausted the information in this guide, you
can get further information and other help in the following locations.
Compaq Technical Support
In North America, call the Compaq Technical Phone Support Center at
1-800-OK-COMPAQ. This service is available 24 hours a day, 7 days a week.
For continuous quality improvement, calls may be recorded or monitored.
Outside North America, call the nearest Compaq Technical Support Phone
Center. Telephone numbers for worldwide Technical Support Centers are
listed on the Compaq website. Access the Compaq website by logging on to
the Internet at
http://www.compaq.com
Be sure to have the following information available before you call Compaq:
I Technical support registration number (if applicable)
I Product serial number
I Product model name and number
I Applicable error messages
I Add-on boards or hardware
I Third-party hardware or software
I Operating system type and revision level
Compaq Website
The Compaq website has information on this product and the latest drivers and
Flash ROM images. You can access the Compaq website by logging on to the
Internet at
http://www.compaq.com
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
About This Guide xi
Compaq Authorized Reseller
For the name of your nearest Compaq authorized reseller:
I In the United States, call 1-800-345-1518.
I In Canada, call 1-800-263-5868.
I Elsewhere, see the Compaq website for locations and telephone
numbers.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: a-frnt.doc Last Saved On: 6/22/00 1:54 PM
1
Chapter
Compaq ProLiant Clusters for
SCO UnixWare 7 U/ML330
Clustering Overview
TM
This chapter introduces the Compaq ProLiant Clusters for SCO UnixWare 7
U/ML330 Quick Install. This chapter identifies the components that make up
the cluster configuration and defines how those components are configured in
the cluster. Cluster components include servers, reliable internal storage,
cluster interconnect, and software.
Overview of Compaq ProLiant Clusters
for UnixWare 7
A cluster is a collection of servers, storage, and operating system and
management software that allows independent servers and storage to act as a
single system. The cluster presents a single-system image to clients; provides
protection against hardware, operating system, middleware, and application
failures; and provides configuration options for load balancing.
Clustering is an established technology that provides one or more of the
following benefits:
I Availability
I Scalability
I Manageability
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
1-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
I Investment protection
I Operational efficiency
TM
The reliability of the SCO UnixWare 7 NonStop Clusters technology ensures
that your applications and data are protected from multiple error conditions.
For more details on Compaq ProLiant Clusters for SCO UnixWare 7, see the
Compaq High Availability website at
http://www.compaq.com/highavailability
Cluster Configuration
The Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install
provides reliable storage for the cluster using cross-node mirroring (CNM) of
internal SCSI disks. This entry level cluster configuration includes two
Compaq ProLiant ML330 servers directly connected with an Ethernet
crossover cable.
Hardware components include:
I Two identical Compaq ProLiant ML330 servers with an embedded
network interface controller (NIC) in each server used as the cluster
interconnect
I At least one internal SCSI hard drive per server, 9.1 GB or greater
I At least one Compaq NC3123 Fast Ethernet NIC PCI, 10/100 WOL
installed in slot 5 of each server for public local area network (LAN)
access
I One Ethernet crossover cable (provided in the cluster kit)
I One Cluster Integrity (CI) serial cable (provided in the cluster kit)
Software components include:
I SCO UnixWare 7.1.1 with Mirroring Option or the Online Data
Manager (ODM) Media Kit (provided in the cluster kit)
TM
I SCO UnixWare 7 NonStop Clusters 7.1.1+IP Media Kit (provided in
the cluster kit)
I Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs
(provided in the cluster kit)
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Clustering Overview 1-3
TM
I Compaq SmartStart and Support Software CD (provided with the
Compaq ProLiant server)
I Compaq Management CD (provided with the Compaq ProLiant server)
TM
NOTE: SCO UnixWare 7 and UnixWare 7 NonStop Clusters software licenses must be
purchased separately through your SCO reseller or distributor. To locate a convenient SCO
reseller or distributor in order to purchase licenses, see the SCO website at
http://www.sco.com
The Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Kit
configuration uses a shared storage technique called cross-node mirroring
(CNM). This configuration supports two Compaq ProLiant ML330 servers as
cluster nodes and a dedicated interconnect using the embedded NIC in each
server connected by one Ethernet crossover cable (Figure 1-1). A CI serial
cable is required to maintain cluster integrity. This configuration requires a
Compaq NC3123 Fast Ethernet NIC PCI, 10/100 in each node for access to the
public network.
Node 1 Node 2
CI Cable
Ethernet Crossover
Cable
To Public Network
Figure 1-1. Hardware components of the entry-level CNM configuration
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
1-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
TM
The CNM feature of the SCO UnixWare 7 NonStop Clusters software
mirrors data between disks in the two nodes. Figure 1-2 depicts a cluster in
which the data on the disks in node 1 is replicated on the disks in node 2.
Because the replicated, or mirrored, data is kept synchronized between the two
servers, current data is available even if one of the nodes fails.
Node 1 Node 2
CI Cable
Mirror
Ethernet Crossover
Cable
To Public Network
Figure 1-2. Reliable storage configuration in clusters using cross-node
mirroring
Compaq ProLiant ML330 Servers
The Compaq ProLiant ML330 delivers the latest performance features at an
affordable price. This business-critical server provides Intel Pentium III
technology, Error Checking and Correcting Memory, easy expandability, and
leading server management tools. Server features include:
I Intel Pentium III processor with 133-MHz front side system bus
I Capacity for four 18-GB hard drives and one 9-GB hard drive for a
maximum capacity of 81 GB of internal storage
I Three available removable media bays
I IDE CD-ROM drive
I 1.44-MB, 3.5-inch diskette drive
I Embedded PCI 10/100 Wake-On-LAN (WOL) NIC
I Integrated Single Channel Wide-Ultra2 SCSI Controller
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Clustering Overview 1-5
I Integrated ATI Rage XL Video Controller
I Three available 32-bit PCI slots and two 64-bit PCI slots
I CE Mark compliant power supply
Cluster Interconnect
Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330 use a
dedicated, private Ethernet interconnect network. The Ethernet interconnect
uses the embedded NICs and an Ethernet crossover cable to connect the two
nodes.
The cluster nodes use the interconnect data path to support the single-system
image capabilities of the cluster, including:
I Cross-node mirroring
I Cluster-wide file system
I Cluster-wide process management, migration, and load balancing
I Cluster-wide networking and Cluster Virtual IP (CVIP)
I Cluster-wide system administration and management
Ethernet Crossover Cable
The Ethernet crossover cable provides the node-to-node communication data
path for the cluster.
Cluster Integrity Serial Cable
The CI serial cable is required to prevent a condition known as split-brain.
Split-brain is a condition where both nodes in a two-node cluster think they are
the root node and both try to operate as the root node. Since the active root
node mounts the root file system and runs several critical cluster-wide
functions, two nodes trying to behave as the root node is undesirable.
NOTE: The CI serial cable may be referred to as the split-brain avoidance (SBA) serial
cable in UnixWare software and documentation.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
1-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
LAN Connection
A Compaq NC3123 Fast Ethernet NIC PCI, 10/100 WOL must be installed in
slot 5 of each server prior to cluster installation to enable the cluster to access
a public LAN. These NICs must be on a different subnet from that of the
embedded Ethernet node interconnect. Multiple public LAN controllers can be
installed after cluster installation is complete. For a list of certified NICs, see
the Compaq High Availability website at
http://www.compaq.com/highavailability
SCO UnixWare Software
TM
SCO UnixWare 7 and the SCO UnixWare 7 NonStop Clusters software
provide the operating environment for the Compaq ProLiant Clusters for
TM
SCO UnixWare 7. The UnixWare 7 NonStop Clusters software provides the
technology to:
I Perform single-system-image operations
I Perform failover
I Define and modify cluster members
I Manually control and administer the cluster
I View the current state of the cluster
This software is included in the Compaq ProLiant Clusters for SCO
UnixWare 7 U/ML330 Kit.
TM
NOTE: SCO UnixWare 7.1.1+IP NonStop Clusters software only runs on
SCO UnixWare 7.1.1. Earlier versions of UnixWare are not supported.
TM
NOTE: SCO UnixWare 7 and UnixWare 7 NonStop Clusters software licenses must be
purchased separately through your SCO reseller or distributor. To locate a convenient SCO
reseller or distributor in order to purchase licenses, see the SCO website at
http://www.sco.com
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Clustering Overview 1-7
Compaq Software
Compaq offers an extensive set of features and optional tools to support the
configuration and management of your Compaq ProLiant Clusters for
SCO UnixWare 7:
I Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install
Image CDs
I Compaq SmartStart and Support Software CD
I Compaq Management CD
Compaq ProLiant Clusters for SCO UnixWare 7
Quick Install CDs
The Compaq ProLiant Clusters for SCO UnixWare 7 Quick Install CDs
provide rapid and simplified cluster installation. These CDs contain all the
necessary software already configured for immediate cluster boot. An
installation wizard allows you to enter parameters and licenses specific to your
configuration.
TM
The Quick Install CDs also include the NonStop Cluster Verification Utility
(NSCVU) and the UPS-initiated shutdown software (NSCUPS).
NonStopTM Cluster Verification Utility
The NSCVU is automatically installed during cluster installation. NSCVU
validates several key aspects of the Compaq ProLiant Clusters for SCO
UnixWare 7 and their components.
The utility is run from any node of a fully installed Compaq ProLiant Cluster
for SCO UnixWare 7.
The NSCVU tests the cluster configuration in the following categories:
I Connectivity tests verify that the two nodes in the cluster can
communicate over Ethernet paths.
I System software tests verify that SCO UnixWare 7 and UnixWare 7
TM
NonStop Clusters have been correctly installed.
For further information on running NSCVU, refer to the online documentation,
nscvu man-page, which is loaded during the Quick Install.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
1-8 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
UPS-Initiated Shutdown Software
NSCUPS is automatically installed during cluster installation. NSCUPS
provides a graceful shutdown of the cluster when a specified amount of battery
backup time is left.
For further information on using the NSCUPS, refer to the online
documentation, nscups man-page, which is loaded during the Quick Install.
Compaq SmartStart and Support Software CD
Compaq SmartStart is located on the SmartStart and Support Software CD
shipped with Compaq ProLiant servers. Use SmartStart's step-by-step process
to configure the servers before using the Quick Install CDs. For information
concerning SmartStart, refer to the Compaq Server Setup and Management
pack that came with your server.
Options ROMPaq Utility
TM
The SmartStart and Support Software CD contains the Options ROMPaq
utility. Options ROMPaq updates the firmware on the hard drives.
Compaq Management CD
TM
Compaq Insight Manager is located on the Compaq Management CD
shipped with Compaq ProLiant servers. Compaq Insight Manager is an
easy-to-use, console-based software utility for collecting server and cluster
information. Compaq Insight Manager performs the following functions:
I Monitors fault conditions and system status
I Monitors shared storage and interconnect adapters
I Forwards server alert fault conditions
I Remotely controls servers
In Compaq servers, each hardware subsystem, such as disk storage, system
memory, and system processor, has a robust set of management capabilities.
Compaq Insight Manager notifies the system administrator of impending fault
conditions and keeps the server up and running in the unlikely event of a
hardware failure.
For information concerning Compaq Insight Manager, refer to the Compaq
Server Setup and Management package.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Clustering Overview 1-9
Resources for Application Installation
The client/server software applications are among the key components of any
cluster. Compaq is working with its key software partners to ensure that
cluster-aware applications are available and that the applications work
seamlessly on Compaq ProLiant Clusters for SCO UnixWare 7.
Compaq white papers provide information about installing applications in
Compaq ProLiant Clusters for SCO UnixWare 7. Visit the Compaq High
Availability website to download cluster-related white papers and other
technical documents at
http://www.compaq.com/highavailability
IMPORTANT: Some software applications may need to be updated to take full advantage
of clustering. Contact the software vendors to check whether their software supports SCO
TM
UnixWare 7 NonStop Clusters and to ask whether any patches or updates are available
TM
for SCO UnixWare 7 NonStop Clusters operation.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: b-ch1 Architecture of Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/27/00 2:46 PM
2
Chapter
Setting Up Hardware for the Compaq
ProLiant Clusters for SCO UnixWare 7
U/ML330
Setting up a cluster includes setting up hardware components. After setting up
the hardware components, verify that the connections are operating properly.
Use the following sections to set up the cluster:
I Setting Up Components
I Cabling the Components
For specific information about individual components, see the documentation
that came with the component. For information on steps and procedures for
setting up cluster hardware, refer to the documentation that came with the
hardware.
Setting Up Components
The first step in setting up a cluster is preparing the main components of the
cluster, including the servers used as nodes in the cluster.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:56 PM
2-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Setting Up the Nodes
Setting up the cluster nodes includes installing the Compaq NC3123 Fast
Ethernet NIC PCI, 10/100 WOL for connection to the public network, along
with processors, memory, and disk drives. Node setup also includes installing
any other approved adapter cards.
To install the Compaq NC3123 NIC into the server, follow the directions in
the installation guide that came with the NIC. Install the NIC in slot 5 of each
server.
To install processors, memory, disk drives, tape drives, and other adapter
cards, refer to the Compaq documentation that came with these devices. For a
list of certified options, see the Compaq High Availability website at
http://www.compaq.com/highavailability
When setting up the nodes, keep in mind:
I The minimum disk capacity per node is 9.1 GB.
I The public LAN NICs must be Compaq NC3123 NICs if installed prior
to cluster Quick Install. Refer to the Compaq High Availability website
at http://www.compaq.com/highavailability for a list of certified NICs that can
be added after the Quick Install.
I The two nodes must be identical in terms of server model, NICs,
processor type and speed, drives used for mirroring, and system
memory.
I Additional options, such as tape drives, other NICs, and Remote Insight
Boards, must be installed after cluster Quick Install.
Cabling the Components
Proper cabling can simplify service and assembly of the cluster, so following
appropriate cabling standards is vital to a successful cluster setup.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:56 PM
Setting Up Hardware for the Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 2-3
Using Labeling Standards
Proper labeling can prevent improper connections and simplify cluster
assembly and service. Make sure to label each server with the correct node
labels that are provided.
Also label both ends of the following cables:
I Ethernet crossover cable
I Cluster Integrity (CI) serial cable
I Keyboard, monitor, and mouse cables
I Server power cables
Each label should identify the server node to which the cable connects.
Cabling the Ethernet Crossover Cable
To cable the Ethernet crossover cable, connect one end of the Ethernet
crossover cable to the embedded NIC in node 1. Connect the other end of the
Ethernet crossover cable to the embedded NIC in node 2. Figure 2-1 illustrates
proper cabling.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:56 PM
2-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Cabling the Cluster Integrity Serial Cable
To cable the CI serial cable, connect one end of the CI serial cable to serial
port connector B on node 1. Connect the other end of the CI serial cable to
serial port connector B on node 2. Figure 2-1 illustrates proper cabling.
Node 1 Node 2
CI Cable
Ethernet Crossover
Cable
To Public Network
Figure 2-1. Cabling the cluster
Cabling the Keyboard, Monitor, and Mouse
To cable the keyboard, monitor, and mouse, refer to the documentation that
came with these devices.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: c-ch2 Setting Up Compaq ProLiant Clusters for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:56 PM
3
Chapter
Installing Software Using the Compaq
ProLiant Clusters for SCO UnixWare 7
U/ML330
TM
Installing the SCO UnixWare 7 NonStop Clusters Quick Install on a
Compaq ProLiant Cluster includes several tasks. Use the following guidelines
for installation:
I Preinstallation Tasks and Considerations
I Obtaining UnixWare 7 Licenses
I Configuring the Servers with SmartStart
I Installing the Cluster with Quick Install
I Verifying Cluster Assembly and Installation
I Registering the Compaq ProLiant Cluster for SCO UnixWare 7
For specific information about individual software components, see the
documentation that came with the component.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
3-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Preinstallation Tasks and Considerations
Before you begin the software installation, be sure to complete assembling the
hardware for the cluster, fill out the Quick Install planning worksheets in
Appendix B of this guide, and have one formatted diskette on hand. Read
through this section to become familiar with the installation procedures.
Table 3-1 lists the default settings used during the Quick Install. These
parameters can be modified after Quick Install is complete by running the
International Settings Manager in the System folder of SCOadmin.
Table 3-1
Quick Install Default Settings
Parameter Default
Locale C Standard
Keyboard United States C
Code Set C
Time Zone Configurable to any US time zone
SCOadmin is also used to configure name servers for the cluster's domain
name after Quick Install is complete.
Obtaining UnixWare 7 Licenses
TM
Before loading and installing the SCO UnixWare 7 NonStop Cluster, obtain
a UnixWare 7 license with Mirroring Option or an OnLine Data Manager
(ODM) license. To locate a convenient SCO reseller or distributor in order to
purchase licenses, see the SCO website at
http://www.sco.com
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 3-3
Configuring the Servers with SmartStart
Before cluster installation, erase any existing configuration on the servers and
configure them using the SmartStart CD that came with the servers.
If the servers were previously configured for another operating system or if the
current configuration is unknown, erase the configuration. To erase the
configuration:
CAUTION: This procedure erases any information currently stored on the
server. To prevent information loss, back up important files before attempting
installation. Insert the Server Profile Diskette that came with the server when
prompted.
1. Power on the server.
2. Insert the SmartStart CD in the CD-ROM drive and wait for SmartStart
to boot.
3. Select the language (English, for example). The Regional Settings
Screen displays.
4. Click Next, then click Continue. The license agreement displays.
5. Accept the license agreement.
6. Select the Run System Erase Utility icon and click OK.
7. Click the Yes button when the System Erase Utility window displays.
8. Click the Yes button when prompted to continue.
To configure the server using SmartStart:
1. Power on the server.
2. Insert the SmartStart CD in the CD-ROM drive.
3. Press F1 when prompted and wait for SmartStart to boot.
4. Select the correct language.
5. Select the country and keyboard type.
6. Set the date and time, select the daylight savings time adjustment, and
click Next.
7. Click Continue.
8. Read the software license, select the I Agree check box, and click OK.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
3-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
9. Select the Manual Configuration installation path and click the Begin
button.
10. Select SCO from the menu.
11. Select SCO UnixWare 7.1.1 and click Next.
12. Click Continue. The server reboots two times. Wait for the system
partition installation to complete. The server reboots and the Create
Support Software window displays.
13. Click Next. The Release Notes window displays.
14. Remove the SmartStart CD from the CD-ROM drive and click
Continue. The server reboots.
Installing the Cluster with Quick Install
Before beginning the software installation, be sure to have the Quick Install
planning worksheets on hand. Have the following items available:
I Cluster name and CVIP address
I Node 1 hostname and IP address for the public network
I Node 2 hostname and IP address for the public network
I Node 1 hostname and IP address for the cluster interconnect
I Node 2 hostname and IP address for the cluster interconnect
CAUTION: The public network IP address for node 1 and node 2 and the CVIP
address must be on the same Ethernet subnet. The cluster interconnect IP
addresses for node 1 and node 2 must be on a different subnet.
TM
I UnixWare and NonStop Clusters (NSC) licenses (An add-on
Mirroring Option license or ODM license must be added if the
UnixWare license does not include mirroring.)
I Passwords and system owner information
I NSC SNMP agent configuration information
I One formatted diskette
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 3-5
Installing the First Node
To install the software on the first node:
NOTE: Node 2 installation can be performed simultaneously with node 1 installation to
save time.
1. Power on node 1 and insert the Quick Install CD for node 1. Wait while
node 1 boots from the CD. A warning displays indicating that data will
be lost.
2. Press Enter to continue, or power off the system to abort the
installation. The software begins to load and a progress bar displays
indicating the installation progress. When all software has been loaded,
several screens display requesting necessary information.
3. Provide the necessary information for the following screens. Each
screen displays the fields and a brief description of each field as it is
selected for entry. For detailed help, press F1.
a. Screen 1: Read responses from previously saved floppy?
This screen gives the opportunity to restore responses from a
previous installation.
Enter No to skip reading responses or if this is the first installation.
Responses can be saved later.
Enter Yes to read the answers from a floppy and present them as
defaults in the remaining screens.
Enter Force to read the answers from a floppy and apply them
without modification. (The date is assumed to be correct on the
system and is not modified.)
b. Screen 2: Date, Time, and Time Zone
Modify the current date, time, and time zone as necessary. Only US
time zones are available during Quick Install. Time zone information
can be changed after Quick Install by using the SCOadmin tools. For
more information, see "Preinstallation Tasks and Considerations."
c. Screen 3: Cluster name
Enter the name of the cluster.
d. Screen 4: System owner identity and passwords
Enter the full name of the system owner, the system owner login id,
and the system owner and root passwords. (Passwords are not
displayed and must be repeated to verify that they are entered
correctly.)
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
3-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
e. Screen 5: IP interconnect
Enter the node 1 hostname and IP address for the cluster
interconnect, the node 2 hostname and IP address for the cluster
interconnect, and the netmask. The addresses must be on the same
network.
f. Screen 6: Physical Network configuration
Enter the external network configuration: domain name, CVIP
address, netmask, node 1 hostname and IP address for the public
network, node 2 hostname and IP address for the public network,
and default route.
g. Screen 7: NSC SNMP agent configuration
The NSC SNMP agent configuration screen from the included
package is executed.
h. Screen 8: Save responses
Responses can be saved, except for the date, to a formatted diskette
for future installations. Unencrypted passwords are not saved.
4. A final screen displays indicating that the installation is complete.
5. Remove the CD and press Enter to reboot.
6. The SCOadmin license manager runs automatically. Enter the node 1
UnixWare license (and the add-on Mirroring Option license or ODM
license, if required), the node 2 UnixWare license, and the NSC license.
After this information is entered, the node continues booting.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
Installing Software Using the Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 3-7
Installing the Second Node
To install the software on the second node:
IMPORTANT: Do not reboot node 2 until after the installation on node 1 is complete and
node 1 has been rebooted.
NOTE: Node 2 installation can be performed simultaneously with node 1 installation to
save time.
1. Power on node 2 and insert the Quick Install CD for node 2. Wait while
node 2 boots from the CD. A warning displays indicating that data will
be lost.
2. Press Enter to continue, or power off the system to abort the
installation.
The software begins to load and a progress bar displays indicating the
installation progress. When the software has been loaded, a screen
displays a request for the IP interconnect information.
3. Enter the IP interconnect address for node 1, the IP interconnect address
for node 2, and the netmask. The option to load or save this information
to a floppy is not available.
Wait until a message displays indicating that the installation is complete.
4. Remove the CD and press Enter to reboot.
IMPORTANT: If any nodes are shut down and then brought back into the cluster,
including the first time the second node joins the cluster, make sure that the system has
fully recovered before shutting down any other part of the system. Full recovery includes
the recovery of any mirrored file system, which may take an extended amount of time to
complete.
To make sure that the mirroring has completed, enter the vxprint
command and check that the TUTILO column has no ATT or ATT1
entries.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
3-8 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Verifying Cluster Assembly
and Installation
After the cluster is fully assembled and installed, verify that the cluster is
TM
assembled and installed properly. The NonStop Cluster Verification Utility
(NSCVU) is automatically installed during software installation.
Verifying the Cluster Assembly
Run the nscvu command to verify that all of the cluster resources are present.
Resources include nodes, processors, memory, controllers, and storage units. If
any resources are missing or if file system failover is not operating correctly,
refer to Chapter 5 of this guide for troubleshooting help.
IMPORTANT: Do not run the NSCVU in the failover mode until mirroring is complete. To
make sure that the mirroring has completed, enter the vxprint command and check that
the TUTILO column has no ATT or ATT1 entries.
Registering the Compaq ProLiant Cluster
for SCO UnixWare 7
After the cluster is verified, go to the Compaq High Availability website to
register the cluster. Compaq sends notification to registered users as software
TM
updates and additional support for SCO UnixWare 7 NonStop Clusters is
made available. The website is located at
http://www.compaq.com/highavailability
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: d-ch3 Installing Quick Reference on Compaq ProLiant Clusters for SCO UnixWare 7 with the ML330.doc Last
Saved On: 6/27/00 2:47 PM
4
Chapter
Managing Compaq ProLiant Clusters for
SCO UnixWare 7 U/ML330
Both Compaq and SCO provide a variety of management software to simplify
the management of Compaq ProLiant Clusters for SCO UnixWare 7. SCO
cluster management software includes:
I Clusterized SCOadmin
I Event Processor Subsystem
TM
I NonStop Clusters Management Subsystem
I Clusterized and cluster-specific command line utilities
Compaq provides the following management capabilities customized for use
with Compaq ProLiant Clusters for SCO UnixWare 7.
I Clusterized Compaq Insight Manager Support
I UPS-Initiated Shutdown Configuration
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
4-2 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
TM
SCO UnixWare 7 NonStop Clusters
Management Software
The single-system image of the Compaq ProLiant Cluster makes managing a
cluster similar to managing a single-node non-cluster UnixWare 7 system. The
standard SCO documentation is useful for performing the management tasks.
TM
Some procedures have been changed to support SCO UnixWare 7 NonStop
Clusters software. These changes are documented in the SCO UnixWare 7
TM
NonStop Clusters System Administrator's Guide.
Clusterized SCOadmin
TM
The SCOadmin software provided with SCO UnixWare 7 NonStop Clusters
TM
has been clusterized for use in a NonStop Clusters environment. SCOadmin
is documented by help information available from within SCOadmin and by
TM
the online documentation supplied with SCO UnixWare 7 NonStop Clusters
software.
The SCOadmin software includes the following managers:
I Account Manager
I Filesystem Manager
I License Manager
I Login Session Viewer
I Mail Manager
I Netscape Server Administrator
I Print Job Manager
I Printer Setup Manager
I SCOadmin Setup Wizard
I Task Scheduler
I VERITAS Volume Manager
I Virtual Domain User Manager
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 4-3
The following SCOadmin folders provide additional management tools:
I Clustering
I Compaq
I Hardware
I Networking
I Software Management
Event Processing Subsystem
The Event Processing Subsystem (EPS) is installed during cluster installation.
Use the EPS to configure actions and notifications based on system messages
TM
(syslogd). See the SCO UnixWare 7 NonStop Clusters System
Administrator's Guide for more information.
NonStopTM Clusters Management Subsystem
TM
The NonStop Clusters Management Subsystem (NCMS) is installed as part
TM
of SCO UnixWare 7 NonStop Clusters and includes:
I Keepalive Manager
I Keepalive Configuration Manager
I System Availability Monitor Viewer
I Configuration Manager
On the system, NCMS is started by entering the ncms command at a command
line prompt, or by selecting an application from the Clustering folder in the
SCOadmin management program.
Keepalive Manager
TM
The SCO UnixWare 7 NonStop Clusters Keepalive Manager provides a
graphical user interface to monitor the status of applications currently being
managed by the Keepalive subsystem. Applications are placed under
Keepalive control through use of the spawndaemon command. See the SCO
TM
UnixWare 7 NonStop Clusters System Administrator's Guide for more
information on the Keepalive subsystem.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
4-4 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Keepalive Configuration Manager
TM
The SCO UnixWare 7 NonStop Clusters Keepalive Configuration Manager
provides a graphical user interface to create and manage configuration file sets
for applications to be monitored by the Keepalive subsystem.
System Availability Monitor Viewer
TM
The SCO UnixWare 7 NonStop Clusters System Availability Monitor
Viewer displays availability reports for the cluster, nodes, and other devices.
Configuration Manager
TM
The SCO UnixWare 7 NonStop Clusters Configuration Manager provides a
graphical user interface to configure SNMP agents, the EPS, and Compaq
Insight Manager support. See the NCMS help subsystem for additional
information.
SCO Clusterized Commands
TM
SCO UnixWare 7 NonStop Clusters software includes a number of
cluster-specific and clusterized commands to simplify system management in
a cluster environment. The following list identifies the key cluster-specific and
clusterized commands.
I onnode, onall--Executes a command on a specific node or on all nodes
I migrate, kill3--Sends the running process a migrate request signal
I cluster--Displays node state information and the software version
installed
I clusternode_avail--Shows node availability status
I clusternode_num--Displays the current node number
I where--Displays which node is currently serving a file, device, or
process
I spawndaemon--Registers processes for restart
I fast--Executes commands on the node with the smallest load
I fastnode--Returns the number of the node with the smallest load
I clusternode_shutdown--Shuts down a specified node
I nodedown--Halts the specified node without processing
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 4-5
I dbms_guard--Runs the Data Base Management System guard
TM
I ncms--Runs the NonStop Cluster Management Subsystem
I ctsm--Runs the Cluster Time Sync Monitor
The SCO UnixWare commands that are clusterized in SCO UnixWare 7
TM
NonStop Clusters include:
I netstat, inetd, netcfg, rpcbind
I fuser, df, fsck, mknod, sync
I Veritas commands, mount, umount, mountall, umountall
I init, crash, cron
I id tools, pdi commands
I pmd, brand, and so on
I SCOadmin commands
I sar, ps, ipcs, prtconf
I shutdown
The following SCO UnixWare commands interrogate the cluster node on
which they are executed. These commands can be used on any cluster node in
conjunction with the onnode command.
I nfsstat--NFS and RPC kernel interface statistics
I rtpm--Real-time performance monitor
I psradm--SMP processor administration
I psrinfo--SMP processor information
I pexbind--Exclusive processor bind operation
TM
NOTE: Refer to the SCO UnixWare 7 NonStop Clusters manual pages for additional
information on SCO UnixWare commands.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
4-6 Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide
Compaq ProLiant Cluster Management
TM
Software for SCO UnixWare 7 NonStop
Clusters
Compaq provides the following cluster management capabilities customized
for use with Compaq ProLiant Clusters for SCO UnixWare. These capabilities
TM
are available on the SCO UnixWare 7 NonStop Clusters media as delivered
from SCO.
I Compaq Insight Manager and Compaq Insight Manager XE Support
I UPS-Initiated Shutdown Configuration
Compaq Insight Manager Support
Compaq Insight Manager client software runs on Win32 desktop computers
and remotely connects to the Compaq Management Agents running on a
UnixWare server or a Compaq ProLiant Cluster for SCO UnixWare 7.
Compaq Insight Manager Overview
Compaq Insight Manager is the Compaq console-based application for
managing networked devices. Compaq Insight Manager provides intelligent
monitoring and alerting capabilities for the critical systems in a distributed
enterprise.
Compaq Insight Manager consists of a console application and a set of server-
or client-based management data collection agents. Key subsystems are
designed to make system health, configuration, and performance data available
to the agent software. The agents act upon data by initiating SNMP alarms in
the event of faults and by providing updated management information.
Compaq Insight Manager is located on the Compaq Management CD. Install
Compaq Insight Manager on a Win32 desktop computer using the instructions
provided on the CD. The nodes within the cluster appear to Compaq Insight
Manager as separate UnixWare 7 systems.
Refer to the Compaq Insight Manager Users Guide included on the Compaq
Management CD for more information on installing Compaq Insight Manager.
Compaq Confidential Need to Know Required
Writer: Hilary Stead Project: Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 Quick Install Guide Comments:
Part Number: 189018-001 File Name: e-ch4 Managing a Compaq ProLiant Cluster for SCO UnixWare 7.doc Last Saved On: 6/22/00 1:57 PM
Managing Compaq ProLiant Clusters for SCO UnixWare 7 U/ML330 4-7
Clusterized Compaq Management Agents
TM
Compaq Management Agents running on a SCO UnixWare 7 NonStop
Clusters system support the same client-server interface as is supported on a
single server SCO UnixWare 7 system. The client-server interface for Compaq
Insight Manager is SNMP-based, which allows ProLiant servers and clusters
to be managed by other network management client software.
The Compaq Management Agents are installed during the Quick Install and
189018-001
Page 1 - Page 2 -

3prime solutions for all your Digital requirements

     
 